| Sign In | Join Free | My burrillandco.com |
|
...Calibrator Meigaolan buys used and second hand Test and Measurement equipment, including: Spectrum Analysers, Network Analysers, Signal Generators, Oscilloscopes, Calibrators,etc. We buy used test equipment ...
... fixtures. Fast 3.6 µs/point sweeps and a +13 dBm leveled source accelerate compression, intermodulation, and on-wafer TRL/LRM calibrations. Refurbished units ship ISO-17025-calibrated with current firmware,...
...Agilent N5227B PNA combines 900 Hz-to-67 GHz coverage with 128 dB dynamic range and only 0.002 dB trace noise, exposing minute S-parameter shifts without external boosters. A leveled +13 dBm source, dual int...
... with sophisticated baseband generation to deliver calibrated test signals at baseband, IF, and RF frequencies up to 6 GHz. The Agilent/HP E4438C ESG Vector Signal Generator provides an internal baseband gen...
Keysight (Agilent) 83751B 2 GHz To 20 GHz High Power Synthesized Sweeper Description of Keysight Agilent 83751B The Agilent 83751B sweeper brings outstanding synthesized performance to the component-test market...
...Agilent E8364B PNA Network Analyzer 10 MHz to 50 GHz Description of Keysight Agilent E8364B Overview and Features of E8364B PNA Network Analyzer 104 dB of dynamic range and <0.006 dB trace noise <26 usec/point measurement speed, 32 channels, 16,001 points TRM/LRM calibration......
... dB trace noise <26 usec/point measurement speed, 32 channels, 16,001 points TRL/LRM calibration, on-wafer, in-fixture, waveguide, and...
... for the lab and production testing. It has an integrated S-parameter test set for longer-lasting calibrations, exceptional reliability, and improved resistance to ESD. The 8753D gives you a complete solutio...
..., the N1911/12A P-Series power meter provides a measurement frequency range from 50 MHz to 40 GHz with an internal zero and calibration capability....
Keysight (Agilent) 8481A 10MHz-18 GHz, RF Power Sensor (-30 to +20dbm) Description of Keysight (Agilent) 8481A 10MHz-18 GHz, RF Power Sensor (-30 to +20dbm) Features: Excellent SWR for reducing mismatch uncerta...
Y09-PG310A Calibration System For Laser Air Particle Counters The system is based on "dust particle counter performance test method" GB / T6167-2007 and "dust particle counter calibration specification" JJF1190...
... ACPR/EVM targets, while ±0.19 dB amplitude accuracy assures repeatable production and R&D results. Supplied fully tested, freshly calibrated and loaded with...
...Agilent N5224A PNA extends vector-network measurements to 43.5 GHz while delivering a 117 dB receiver dynamic range and ≤ 0.002 dB trace noise—enough to spot hair-thin S-parameter changes even in high-gain o...
...Agilent N5239B PNA-L offers reliable vector-network analysis from 300 kHz to 8.5 GHz with a generous 133 dB dynamic range and just 0.006 dB trace noise, giving clear visibility into small S-parameter changes...
...Agilent E8358A PNA delivers vector-network accuracy from 300 kHz to 9 GHz while its 128 dB dynamic range and sub-0.004 dB trace noise expose subtle S-parameter variations without external boosters. Fast 35 µ...
...Agilent E8363B delivers vector-network accuracy from 10 MHz to 40 GHz with a 110 dB dynamic range and sub-0.006 dB trace noise—quiet enough to spot hair-thin S-parameter changes without external boosters. Fa...
...Agilent E8364B extends vector-network analysis from 10 MHz to 50 GHz while delivering 104 dB of system dynamic range and sub-0.006 dB trace noise—clean enough to expose minute S-parameter shifts in high-gain...
...Agilent N5227A PNA extends vector-network measurements from 10 MHz to 67 GHz while delivering about 122 dB of receiver dynamic range and only 0.002 dB trace noise—quiet enough to expose hair-thin S-parameter...
...-signal details visible, while sweeps as fast as 9 µs per point slash test times. The integrated two-port architecture supports TRL/LRM on-wafer calibrations without extra hardware, and...
... cut test time on filters, amplifiers and mixers. The integrated two-port 2.4 mm test set supports TRL/LRM on-wafer calibration without...