90 Degree RJ45 Ethernet Jack Network Port Unshield with Magnetics white color Descriptions: 10/100Base-Tx RJ45 single port 1X1 Side Entry (Right Angle) w/o led Single port 1X1 Tab-Down RJ45 with internal magnet...
...Transformer Common D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 2x 33 mH min Rated current @ 70°C IR 0.3 A max DC Resistance @ 20°C RDC 2x 2.50 Ω ±15% Rated...
... current |ΔL/L| < 20% Isat 8 A typ. DC Resistance 1 @ 20°C RDC1 99 Ω max. DC Resistance 2 @ 20°C RDC2 3.2 Ω max. DC Resistance 3 @ 20°C RDC3 220 mΩ max. Leakage inductance 100 kHz/ 100 mV LS 3.0 μH max. Insu...
...Transformer RoHS Certification D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 42 μH ±10% Turns ratio N 3 : 1 : 1 ±3% Saturation current |ΔL/L| < 20% Isat 6.6 ...
... 5.0 mΩ max DC Resistance 3 @20℃ RDC3 170 mΩ max Leakage inductance 100KHz/100mV LS 2.0 uH max Insulation test voltage N1,4=>N2,3 UT 1500 V(AC)...
... : W2 n 1 : 50 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 25 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V (AC) E General information: It...
... : W2 n 1 : 30 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 15 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V (AC) E General information: It...
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 80 μH min. Rated current ΔT = 40 K IR 10 A typ. DC Resistance 1 @ 20°C RDC 6 mΩ max. DC Resistance ...
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 100 mV L 100 μH ±10% Turns ratio n 4:1:1:2 ±3% Saturation current |ΔL/L| < 20% Isat 1 A typ. DC Resistance ...
RSRS-V Transformer capacity and no-load/load tester Product Description RSRS-V can test the transformer capacity, type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc. It is s...
KFZ Transformer Load Loss and Transformer Capacity Tester KFZ Transformer Capacity Tester can measure transformer capacity, type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, et...
...current output, voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A. The tester adopts digital Signal Processor Microcomputer, so it can not only test the traditional relays and protec...
Introduction Function: For DC high voltage test and DC leakage current of zinc oxide arresters, power cables, generators, transformers, etc. Features 1. Aluminum alloy carrying box 2. With High Frequency Voltag...
...Transformer Insulation Test Product Description Our company specially launched the insulation resistance tester to carry out insulation, absorption ratio and polarization index withstand voltage leakage test...
...Test Set Introduction: The Manual Withstand Voltage Operation Box For Hipot Test Set is specially provided for various payloads when testing current and voltage transformers, and it is an ideal matching prod...
... warranty. Key Features & Benefits Precision Measurement: Advanced four-wire measurement method with 0.05% accuracy and 0.1μΩ resolution for reliable test data across various scenarios Multi-Range Current Ou...
... generating factories and railways departments. Technical index: Type Capacity (kva) Power supply Output Impedance voltage % Idle current % mode I (A) V (V) I (KA) V (V)...
Transformer Capacity Tester -- Model KFZ Introduction: KFZ Transformer Capacity Tester can measure transformer capacity, type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc. ...
...Transformer Led Driver Electronic Transformer ELECTRICAL SPECIFICATIONS @ 25°C UNLESS OTHERWISE NOTED: PARAMETER TEST COMDITIONS VALUE D.C. RESISTANCE 1-3 @20°C 0.315 OHMS ±10%. D.C. RESISTANCE 6-4 @20°C 7.9...