| Sign In | Join Free | My burrillandco.com |
|
... generator XHHV535-4T is mainly used for underground cable fault test of voltage level of 35kV and below; And the torlley high voltage impulse generator can also be used for DC withstand voltage test of othe...
... generator XHHV535-4T is mainly used for underground cable fault test of voltage level of 35kV and below; And the torlley high voltage impulse generator can also be used for DC withstand voltage test of othe...
... system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identifi...
... system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identifi...
... Feature Electric drive Weight 135kg Volume 86×43×80cm Test standard TAPPI-T803,JIS-P8134,GB2679-7 2.Description: The tester is used for winding cable in low temperature and check whether the surface cracks ...
... Feature Electric drive Weight 87kg Volume 91×55×99cm Test standard JIS-C-3005 2.Equipment Description: The cable ball pressure test chamber is used to testing pressure resistance property under high tempera...
... Feature Electric drive Weight 135kg Volume 86×43×80cm Test standard TAPPI-T803,JIS-P8134,GB2679-7 2.Description: The tester is used for winding cable in low temperature and check whether the surface cracks ...
... Feature Electric drive Weight 87kg Volume 91×55×99cm Test standard JIS-C-3005 2.Equipment Description: The cable ball pressure test chamber is used to testing pressure resistance property under high tempera...
...Cable connector assembly UL1571 28AWG CABLE HSG MX1.0-30P 5011893010 to JAE FIX30HL cable : Feature Description Testing Capability 100% testing of high-performance power supplies Insulation Testing AC-200V f...
Test Type Requirement Open/Short Testing 100% of cables must be tested for open and short circuits Hi-Pot Testing Apply AC-100V for 0.1 seconds Insulation Resistance Test with DC-200V; minimum insulation resist...
...Test Chamber for Wire, Cable and Fibre Optic Cables I. Application 1.1 Applicable to check the cable and fibre optic cable flame FT4 combustion standards of vertical Man Yan and smoke release; 1.2 test metho...
...Test Apparatus Product information: This test device conforms to the standard requirement of GB/T2951.31.9-2008. It is applicable for the PVC wire and cable to do the winding test before the split test in th...
... wire core whose diameter is small and the sector-shaped insulation wire core which can not be used for dumbbell. The apparatus shall be held in a refrigerator before and during the test. The diameter of the...
...Cable Testing Equipment Conductor Resistance Meter Basic Accuracy 0.02% Product description: This resistance tester is a high-precision tester specially designed and developed for ultra-low DC resistance tes...
...Testing Machine I-suntop Optical cable mechanical testing equipmen... 1. Usage of GR-326 Optical Fiber Mechanical Properties Testing Machine: Meet the standards: comply with the gr-326 optical fiber connecto...
...Cable Testing Machine Test Terminal Water Terminal Dry type cable test termination is a new test equipment which is different from traditional water type termination. Water type termination needs Hi-K water ...
...cable repeated bending testing machine optic fiber cable repeat beading detector DESCRIPTION The equipment is used to test optical cable resistance repeated bending properties. By applying repeated bending f...
...Test for a Single Insulated Cable Fire Resistance Test Equipment Detailed Product Description: Material: Stainless Steel Standards: IEC60332-2-1:2004, IEC60332-2-2:2004 Application: Single Wire Or Cable Or F...
... Test Methods for Fire Resistance Characteristics of Electric Wire and Cable, GB/T 5013-2006 Test Standards for Rubber Insulated Cables with Rated Voltages of 450/750V and Below - Extra Flexible Wires, GB/T ...
... whose diameter is small and the sector-shaped insulation wire core which can not be used for dumbbell. The apparatus shall be held in a refrigerator before and during the test. The diameter of the mandrel s...