Product application : Applicable to water pump, washing machine , smoke lampblack machine or other single phase power supply system asynchronous motor and three phase asynchronous motor use single phas power su...
Product application : Applicable to water pump, washing machine , smoke lampblack machine or other single phase power supply system asynchronous motor and three phase asynchronous motor use single phas power su...
... Standard by the introduced advanced foreign techniques and equipment. The device is mainly suitable for low voltage electric net work to improve power factor, reduce reactive loss, and...
...Capacitor General Description Brand of self-healing type low voltage shunt capacitor, made of the advanced metallized film, is produced strictly in accordance with the National Standard and IEC Standard by t...
... Standard by the introduced advanced foreign techniques and equipment. The device is mainly suitable for low voltage electric net work to improve power factor, reduce reactive loss, and...
C41-BA1 1.5UF/500V/300KVAR (ALCONFP-7-300/ CELEM CSP150)FILM CAPACITOR COMPARISON HIGH FREQUENCY AC RATING Technical Parameter Reference Standards GB/T 3984-2004 IEC 60110.1 Operating Temperature Range -4085...
C41-BA1 1UF/600V/300KVAR (ALCONFP-7-300/ CELEM CSP150) CONDUCTION AND INDUCTION HEATING CAPACITOR INDUCTION HEATER Technical Parameter Reference Standards GB/T 3984-2004 IEC 60110.1 Operating Temperature Range ...
...Capacity Range 2.4μF Power Range 200 kVar Rated Voltage 450VAC Capacity Tolerance ±10% Test Voltage between Terminals 1.5UNAC 10s 2~3.5UNDC 10s at 25℃±5℃ Dissipation Factor tgδ≤5×10-4 at 25℃±5℃,1kHz Insulati...
...μF Power Range 300 kVar Rated Voltage 1000VAC Capacity Tolerance ±10% Test Voltage between Terminals 1.5UNAC 10s 2~3.5UNDC 10s at 25℃±5℃ Dissipation Factor tgδ≤5×10-4 at 25℃±5℃,1kHz Insulation Resistance R•C...
... Power Range 150-300 kVar Rated Voltage 400-1100VAC Capacity Tolerance ±10% Test Voltage between Terminals 1.5UNAC 10s 2~3.5UNDC 10s at 25℃±5℃ Dissipation Factor tgδ≤5×10-4 at 25℃±5℃,1kHz Insulation Resistan...
... Range 0.1μF~0.3μF Power Range 100kVar Rated Voltage 400-1100VAC Capacity Tolerance ±5% ~ ±10% Test Voltage between Terminals 1.5UNAC 10s 2~3.5UNDC 10s at 25℃±5℃ Dissipation Factor tgδ≤5×10-4 at 25℃±5℃,1kHz ...
...Capacitor Technical Parameter Reference Standards GB/T 3984-2004 IEC 60110.1 Operating Temperature Range -40℃~85℃ Capacity Range 1.2-21μF Rated Power 500kVar Rated Voltage 400-1100VAC Capacity Tolerance ±10%...
...Capacitor Technical Parameter Reference Standards GB/T 3984-2004 IEC 60110.1 Operating Temperature Range -40℃~85℃ Capacity Range 1.2-21μF Rated Power 500kVar Rated Voltage 400-1100VAC Capacity Tolerance ±10%...
... Voltage 400-1100VAC Capacity Tolerance ±5% ~ ±10% Test Voltage between Terminals 1.5UNAC 10s 2~3.5UNDC 10s at 25℃±5℃ Dissipation Factor tgδ≤5×10-4 at 25℃±5℃,1kHz Insulation Resistance R•C≥3000s,at 100VDC,25...
...Power Range 500kVar Rated Voltage 400-1100VAC Capacity Tolerance ±5% ~ ±10% Test Voltage between Terminals 1.5UNAC 10s 2~3.5UNDC 10s at 25℃±5℃ Dissipation Factor tgδ≤5×10-4 at 25℃±5℃,1kHz Insulation Resistan...
...Capacitor Technical Parameter Reference Standards GB/T 3984-2004 IEC 60110.1 Operating Temperature Range -40℃~85℃ Capacity Range 0.33μF~2.4μF Power Range 300kVar-400 kVar Rated Voltage 400-1000VAC Capacity T...
...℃ Capacity Range 6.3μF Power Range 500kVar Rated Voltage 700VAC Capacity Tolerance ±10% Test Voltage between Terminals 1.5UNAC 10s 2~3.5UNDC 10s at 25℃±5℃ Dissipation Factor tgδ≤5×10-4 at 25℃±5℃,1kHz Insulat...
...40℃~85℃ Capacity Range 5.6μF Power Range 500kVar Rated Voltage 700VAC Capacity Tolerance ±10% Test Voltage between Terminals 1.5UNAC 10s 2~3.5UNDC 10s at 25℃±5℃ Dissipation Factor tgδ≤5×10-4 at 25℃±5℃,1kHz I...
...power electronic equipments IGBT Snubber Absorption Capacitor Technical Parameter Reference Standards IEC61071 .GB/T17702 Operating Temperature Range -40℃~+85℃ (Max. +105℃) Capacity Range 0.047μF -10μF Rated...
...CAPACITOR SMALL SIZE GOOD QUALITY POWER Technical Parameter Reference Standards GB/T 17702 IE 61071 Operating Temperature Range -40℃~70℃ Tmax 85℃ Capacity Range 15μF Rated Voltage 1200VDC Capacity Tolerance ...