Product Description: High-Frequency Transformer The High-Frequency Transformer is a three phase transformer with 3225 PQ rating and is made of high quality copper wire and ferrite core. The rated capacity of th...
... 12v pool light transformers The KSPOWER - LT series triac dimmable led driver 60 80 96 Watt is one constant voltage solution, single channel, accept universal AC input voltage range from 100V to 277V, outpu...
...Transformer with mA Output Class 0.1 Split Core Clip On Current Sensor Q20A-2 designed and manufactured by GFUVE meets the latest safety and performance standards which can measuring AC currents up to 200A. ...
...: Main Parameter Parameters KCT-26-12 Rated primary Current 6(200)A/2mA Ratio 3000:1 Voltage Insulation AC >3000V Accuracy (ratio error ) ±0.5% Accuracy (phase error ) 45’ Coil Resistance ≤250Ω...
...: Main Parameter Parameters KCT-26-12 Rated primary Current 6(200)A/2mA Ratio 3000:1 Voltage Insulation AC >3000V Accuracy (ratio error ) ±0.5% Accuracy (phase error ) 45’ Coil Resistance ≤250Ω...
... the current directly • It is with the diode to save people's life • Meet the ROHS requirement • High accuracy at 10-130% of rated current • AC isolation resistance: 3KV for 60s • Swing open for...
... type Output : down-lead output parameter: Primary current Secondary current Class % 5A 2mA 0.2,0.5 5A 2.5mA 0.2,0.5 5A 5mA 0.2,0.5 10A 4mA 0.2,0.5 10A 5mA 0.2,0.5 10A 10mA 0.2,0.5 Our advantage service We h...
...AC Current Probe clamp transformer MODEL Q8A-2 Characteristic :apply to test on line below 5A 10A Jaw:Φ8mm Size :45mm×158mm×25mm Load capacity: ≤4Ω Installation method:clamp type Output :down-lead output par...
... type Output : down-lead output parameter: Primary current Secondary current Class % 5A 2mA 0.2,0.5 5A 2.5mA 0.2,0.5 5A 5mA 0.2,0.5 10A 4mA 0.2,0.5 10A 5mA 0.2,0.5 10A 10mA 0.2,0.5 Our advantage service We h...
...AC Current Probe clamp transformer MODEL Q8A-2 Characteristic :apply to test on line below 5A 10A Jaw:Φ8mm Size :45mm×158mm×25mm Load capacity: ≤4Ω Installation method:clamp type Output :down-lead output par...
...Transformer for Control and monitoring applications 7492550500 Characteristics Primary current rating to 45A Frequency 47Hz - 400Hz UL Class F 155°C Insulation System Operating temperature: -40 °C to +125 °C...
... Transformer 7492551000 Characteristics Primary current rating to 45A Frequency 47Hz - 400Hz UL Class F 155°C Insulation System Operating temperature: -40 °C to +125 °C Low profile, compact, THT form factor ...
...Transformer for Motor Controls Characteristics Primary current rating to 45A Frequency 47Hz - 400Hz UL Class F 155°C Insulation System Operating temperature: -40 °C to +125 °C Low profile, compact, THT form ...
...Transformer for Control and monitoring applications Characteristics Primary current rating to 45A Frequency 47Hz - 400Hz UL Class F 155°C Insulation System Operating temperature: -40 °C to +125 °C Low profil...
... Transformer Characteristics Primary current rating to 45A Frequency 47Hz - 400Hz UL Class F 155°C Insulation System Operating temperature: -40 °C to +125 °C Low profile, compact, THT form factor Dielectric ...
...Transformer Features: • Meet the standard IEC62053 and ANSI C12.20 • High accuracy class ,wide linearity • Superitor stability ,separate the external magneitc field interference • Measure the current directl...
High Accuracy Three Phase Precision Current Transformer For Motor Protection Features: Low Cost High accuracy class ,wide linearity Superitor stability ,separate the external magneitc field interference ...
...Transformer For Air Conditioning A world famous MINI design plastic case current transformer, snap on body, be wildly used in generators. Rated Frequency 50/60Hz Rated test voltage 3kV AC. (1 min) Rated shor...
...250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the CT and PT Rated current: 5A, 1A Rated voltage: 100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V Multip...
...250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the CT and PT Rated current: 5A, 1A Rated voltage: 100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V Multip...