| Sign In | Join Free | My burrillandco.com |
|
...CT PT Testing Equipment Secondary Voltage Drop Tester & Instrument Product Description Our secondary voltage drop tester can realize three-phase three-wire, three-phase four-wire and single-phase full-automa...
... resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for voltag...
...class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete an...
...current transformer and voltage transformer at rated burden and working burden in one time test. Fully Automatic CT PT Testing Equipment can automatically evaluate the test results according to the selected ...
ZXHQ-Y Transformer Field Calibrator Product introduction ZXHQ-Y is a Multifunctional Current and Voltage Transformer Characteristic Tester designed in accordance with IEC60044-1 / GB1208, IEC60044-2GB1207, IEC6...
... engineered to provide comprehensive testing and analysis capabilities for current transformers (CTs) and potential transformers (PTs). With its cutting-edge technology and precise measurement capabilities, ...
...CT PT Analyzer HYVA-402V 2. Equipment Description: 1 Turns Ratio, ratio error and phase error test 2 Polarity test for CT 3 Excitation curve and knee voltage measurement in power frequency for CT 4 Error cur...
...CT PT analyzer Comprehensive Characteristic Tester Main features Support for detecting CT and PT both 1. Three sets of CT tests can be tested at the same time, finished one time, and the operation is simple....
CT PT Analyzer HYVA-404 Tests for Current Transformer: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary l...
...Test Set CT PT Analyzer Test for current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Secondary loop burden...
...CT PT Metering Unit is a crucial component in electrical systems, providing reliable current and voltage protection. Designed with a TOROIDAL coil structure, this unit ensures accurate measurement and effici...
Automatic Portable CT On-Site Transformer Test Equipment for Testing of CT’s Radio/Angle Error in Accuracy Class 0.05 Specifications: Current Mutual-inductor On-site Calibration Device The product is mainly use...