| Sign In | Join Free | My burrillandco.com |
|
Yixing ICS Refrigeration Quality Counter Flow Evaporative Condenser Heat Exchanger Product Description Yixing ICS Refrigeration Quality Counter Flow Evaporative Condenser Heat Exchanger Evaporative condenser is...
Hot Sale Commercial hot-dip stainless steel coil /galvanizing steel coil Evaporative Condenser Product Description Stainless steel coil /galvanizing steel coil Evaporative Condenser Evaporative condenser is an ...
Ss321 Diameter 6000mm Eliminator Filter 150mm Height Ss321 Diameter 6000mm Eliminator Filter 150mm Height Description Product Name: Demister Mist Eliminator Size: Diameter 6000mm Material: SS321 Specific Area: ...
ASTM A269 TP304 Extruded Fin Tube Chemical Composition Grade UNS Designation C Mn P S Si Cr Ni Mo Other TP304 S30400 0.08 2 0.045 0.03 1 18.020.0 8.011.0 ... ... ASTM A269 TP304 Extruded Fin Tube FAQ 1. What ...
Typical Module Dimension Type:Counterflow Fill Materials:PVC Color Black Length: 1998mm (n x 55.5mm) Height: 500 mm up to 1000mm (Fixed). Width(Stacking): 900mm (n x 18mm) Working Temperature: Standard 55 High...
...CT Velomitor Velocity Transducer Specification If you have any further questions, please don't hesitate to contact us. Measures casing vibration velocity on cooling tower and air-cooled heat-exchanger fan as...
... tower,FRP counter flow cooling tower,round shape or square shape cooling tower,steel frame cooling water,water cooling tower,Industrial cooling tower and so on) Product Description Hot sale square cooling t...
... measures casing vibration velocity on cooling tower and air-cooled heat-exchanger fan assemblies that operate at or above 90 rpm (100 to 300 rpm typical). The Velomitor CT Transducer can measure vibration a...
...CT Transducer Machinery Condition Monitoring Description: The Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor Piezo-velocity Sensor. Its design specifically measures cas...
...cooling tower technical parameters Model STG-30 Basic parameter Type Counter current circular cooling tower Nominal flow 23.4m3/h Inlet/outlet temperature 37℃/32℃ Dry-bulb temperature 31.5℃ Wet-bulb temperat...
...cooling tower technical parameters Model STG-150 Basic parameter Type Counter current circular cooling tower Nominal flow 117m3/h Inlet/outlet temperature 37℃/32℃ Dry-bulb temperature 31.5℃ Wet-bulb temperat...
...Cooling Water Tower for sale Product Description The standard water cooling tower can afford the highest temperature is 60°C.If the temperature is higher than 60°C,we suggest you choose the High temperature ...
...cooling tower technical parameters Model STG-40 Basic parameter Type Counter current circular cooling tower Nominal flow 31.21m3/h Inlet/outlet temperature 37℃/32℃ Dry-bulb temperature 31.5℃ Wet-bulb tempera...
... system and to prevent the loss of cooling medium. Soft water is not easy to scale, not blocking the pipeline. Using cold water and spray water evaporation endothermic double cooling method with a high cooli...
... measures casing vibration velocity on cooling tower and air-cooled heat-exchanger fan assemblies that operate at or above 90 rpm (100 to 300 rpm typical).The Velomitor CT Transducer can measure vibration am...
...-00 Bently Nevada Velomitor CT Velocity Transducer Description The Bently Nevada 190501 Velomitor CT Velocity Transducer is a specialized sensor designed to measure casing vibration velocity in cooling tower...
... as a low-frequency version of Bently’s standard Velomitor velocity sensor, so that it can effectively measure vibration on slower-speed machinery (for example cooling towers, air-cooled heat-exchanger fans)...
...Nevada Velomitor CT Transducer Description The 190501-series “Velomitor CT” by Bently Nevada is a low-frequency piezoelectric velocity transducer designed to measure casing vibration velocity in equipment su...
...CT Velocity Transducer Description The Bently Nevada 190501‑11‑00‑00 is a variant of the Velomitor CT line of velocity transducers, which are designed especially for low‑frequency vibration velocity measurem...
... measures casing vibration velocity on cooling tower and air-cooled heat-exchanger fan assemblies that operate at or above 90 rpm (100 to 300 rpm typical).The Velomitor CT Transducer can measure vibration am...