| Sign In | Join Free | My burrillandco.com |
|
Mini current transformer Moisture-proof and vibration-resistant 3 in 1 CT Product Description: 1. Used for a current sensing device for utility energy meter. 2. Moisture-proof and vibration-resistant. 3. Encaps...
Mini current transformer 5A CT 1:2500 turns ratio 0.1 accuracy class for meter​ Characteristics: 1. Used as a current sensing device for utility energy meter; 2. Moisture-proof and vibration-resistant; 3. Encap...
50Hz - 60Hz Low Voltage Protection Devices 15VA - 60VA Current Transformers CA Current Transformers Outline Drawing Of CA62/30-CA104/80 Unit:mm Model A B C D E F G H I J K L M O P CA62/20 78 36 6.6 36 ......
... (see table) ·Rated Voltage: 600V (see table) ·Rated Sec. Current 5A(or 1A on request) ·Security Factor: FS5 ·Working Temperature Range: -20℃~+45℃ ·ABS plastic case, toally ......
760V 27mm Surge Protection Device With 25kA Current Capacity OBV-I25: Uc(maximum continuous operating voltage) 760V Iimp(impulse discharge current for class I test) 25KA In(nominal discharge current for class I...
...120kA Surge Protection Device For Type 1 And Type 2 OBV12.5/120 data: Uc(maximum continuous operating voltage) 320V Iimp(impulse discharge current for class I test) 12.5kA Imax(maximum discharge current) 120...
...device Type 1+2 with lightning protection class 3+4 Technical Parameters Model: Maximum continuous voltage AC Uc V 275/320/385/440 SPD to EN 61643-11 Type 1+2 SPD to IEC 61643-1 class I+II Lightning impulse ...
.... When the device is in operation, it can detect the output signals of each branch sensor in real time. When the branch insulation is normal, the current flowing through the sensor is equal in magnitude and ...
.... When the device is in operation, it can detect the output signals of each branch sensor in real time. When the branch insulation is normal, the current flowing through the sensor is equal in magnitude and ...
...Current Low Resistance Flat Copper Wire Inductor Coil The flat wire inductor coil is wound, the turns and turns are closely flat, increasing the effective cross-sectional area of the wire, making full use of...
...Current Source 2x8 ch, The input voltage range is 18 to 30 volt dc and the input current source is 6 mA at 24 V. The inputs are divided into two individually isolated groups with eight channels and one volta...
TOPWORX DXP-L21GN4S162 Valve Limit Switch | Industrial Position Monitoring The TOPWORX DXP-L21GN4S162 Valve Limit Switch is an industrial valve position monitoring solution designed to provide reliable feedback...
...devices or presents data from transmitters in inaccessible areas. Functional Specifications Current Consumption 17.5 mA Power Requirements External power required; operates at 9.0–32.0 Vdc on a Fieldbus term...
... Capacity 45mAh Nominal Voltage 3.7V Initial Impedance (23±2°C) Limited Charge Voltage 4.20V Discharge Cut-off Voltage 3.0V Charge Current Standard Charge: 0.2C Rapid Charge: 1C Standard Charge 0.2C(constant...
... Nominal Capacity 220mAh-851724 Nominal Voltage 3.7V Initial Impedance (23±2°C) Limited Charge Voltage 4.20V Discharge Cut-off Voltage 3.0V Charge Current Standard Charge: 0.2C Rapid Charge: 3C Standard Char...
... as additives, after high temperature sintering in the air made of polycrystalline semiconductor ceramic elements. Varistor is the 1 kind of voltage limiting protection device. The varistor and the protected...
... (Thickness × Width × Length) Nominal Voltage 3.7V Nominal Capacity 2000mAh Limited Charge Voltage 4.2V Cut-off Voltage 2.75V Standard Charge 0.5C (1000mAh) Max. Charge Current 1.0C (2000mAh) Standard Discha...
...Limited Time Offe Product Description **Model:** 14.6V 6A Charger **Voltage:** 14.6V ± 0.1V **Current:** 6A ± 0.1A **Compatibility:** Suitable for 12.8V/14.4V Lithium Iron Phosphate (LiFePO₄) batteries. **Ch...
...-852550 Nominal Voltage 3.7V Initial Impedance (23±2°C) Limited Charge Voltage 4.20V Discharge Cut-off Voltage 3.0V Charge Current Standard Charge: 0.2C Rapid Charge: 3C Standard Charge 0.2C (constant curren...