| Sign In | Join Free | My burrillandco.com |
|
... primary & secondary windings and annular core in the epoxy resin casting body. The product has two secondary windings (one measuring winding and one protective winding). It is widely used for measuring curr...
...used for controlling, protection, measuring functions. P1,P2 primary terminals,S1,S2 secondary terminals P1&S1 same as P2,S2(subtractive polarity). 2. Technical Parameter 1) Rated Primary Current: 5-3000A; R...
... for 12 kV and current measurement and relay protection do ac 50/60 Hz line. · suitable for air-insulated switchgear. · Applicable altitude 2000 meters. · ......
... with a high level of precision and performance to meet the needs of professionals in the field. With a Withstand Voltage of 3kV/50Hz/min, this current transformer ensures safety and durability during operat...
High Accuracy Split Core Current Transformer for Energy Metering Systems The CP Series Low Voltage Current Transformer delivers precise current measurement and energy monitoring capabilities for electrical syst...
CTKD-16 100/5A AC Current Sensor Transformer Split Core Current Coil Sensor 1.Product Description A Split Core Current Coil Sensor is a highly practical and versatile device designed for current measurement in ...
...Current Transformer CY-RCT02 Clamp-on Rogowski Coil Current Transfomers The”RCT02 Clamp-on Flexible Rogowski coil current transformer” are designed for easy installed in tight spaces and without the need for...
..., this current transformer is built to withstand tough environments and provide reliable performance. With accuracy classes of 0.2/0.5 and 0.5/5P10, the MV Current Transformer ensures precise measurement res...
...Used for Protected Circuit/Current Monitoring,split core current transformer Clamp-on Flexible Rogowski coil Current Transformer is an AC current transducer for permanent installation. They combine the benef...
... Technical parameter ADL100-EY Voltage Reference voltage 3*220/380V Reference frequency 50Hz Consumption <4VA(Each phase) Current Input Current 1(6)A,10(80)A Starting Current Connect directly: 0.004 Ib, connect via...
... Technical parameter ADL100-EY Voltage Reference voltage 3*220/380V Reference frequency 50Hz Consumption <4VA(Each phase) Current Input Current 1(6)A,10(80)A Starting Current Connect directly: 0.004 Ib, connect via...
...Transformer Capacity Characteristic Tester , Measure The Capacity Of Distribution Transformers I. Products Description and Application In the process of power transformer working or metering installation, it...
...Transformer Capacity Characteristic Tester , Measure The Capacity Of Distribution Transformers I. Products Description and Application In the process of power transformer working or metering installation, it...
... of power supply equipment below 10KV also can be used for microcomputer protection. This Type is flame retardance anti-moisture, stable performance, no maintenance. LMCK series outdoor current transformers ...
...Current Transformer Product Details LMZJ1-0.5 current transformer is mainly used indoors, especially used in AC circuit with the rated voltage up to 0.5kV and rated frequency of 50Hz for current, energy meas...
Current Transformer Tester and Analyzer MCCT2000 Specifications Output Voltage Output 0~100V (AC) Current Output 0~15A (Peak) Measurement Current Measurement Accuracy ±0.1% Voltage Measurement Accuracy ±0.1% Se...
Current Transformer Tester and Analyzer MCCT2000 Specifications Output Voltage Output 0~100V (AC) Current Output 0~15A (Peak) Measurement Current Measurement Accuracy ±0.1% Voltage Measurement Accuracy ±0.1% Se...
... of power frequency parameters such as the capacity, no-load current, no-load loss, short-circuit loss, impedance voltage, etc. of various transformers. When measuring the transformer capacity and short-circ...
... equipment in 10KV and 35KV AC power system. The current transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary wi...
... measurement and protection of distribution equipment in 35kV or 10kV AC. power system. The combined bushing type current transformer is fit for be installed at the three-phase bushings of the ring switchgea...