| Sign In | Join Free | My burrillandco.com |
|
... an important role in the generation, transmission and distribution of electrical energy. Under load the transformer, dissipates heat and the insulating oil acts as a coolant as well as an effective dielectr...
.../ODM Place of origin Shanghai, PRC. Working capacity 630KVA (cutomization available) Working frequency 50~60HZ Input Voltage 380V±2% Output Voltage 0-420V adjustable Input Current 957.21A Output Current 866....
.../ODM Place of origin Shanghai, PRC. Working capacity 630KVA (cutomization available) Working frequency 50~60HZ Input Voltage 380V±2% Output Voltage 0-420V adjustable Input Current 957.21A Output Current 866....
... of 25*280mm and 55*610mm and a rated breaking capacity of 50KA. It is widely used in outdoor high voltage current limiting and mutual inductor applications. It is especially suitable for RN4 0.5A ~20A. With...
... voltage error calibration for insulating oil tester 2 High voltage measurement error calibration for insulating oil tester 3 Voltage rise rate error calibration for insulating oil tester 4 High voltage cut ...
...tem is applicable to 50Hz power system line voltage is 35kV. Product installation site for outdoor installation height of 1000m above sea level, the maximum variation range of ambient air ......
Technical data The voltage transformers are in accordance with GB20840.3 and IEC60044-2 standards Rated insulation level: 12/42/75, 7.2/32/60kV Rated frequency: 50Hz or 60Hz...
.... Its rated frequency is 50-60HZ, Voltaged: 10KV. So it can be used in 10KV or below 10KV power system, energy measurement and relay protection, small size, light weight. and it is easy to be installed at an...
36kv Out Door Single-Phrase Epoxy Resin Type 1.Product Introduction: This single phase combined CT&VT consists of one semi-insulation VT and one CT, VT connected with CT terminal P1, CT series connected with ph...
12kv Outdoor Single-Phrase Epoxy Resin Type 1. Product Introduction: 2. Technical Data: 1 Installation site: Outdoor 2 Rated Frequency: 50/60hz 3 Burden Power Factor : cos=0.8(lagging) 4 Technical Standard Acc...
Description Epoxy resin casting and fully enclosed construction, is used indoor for measuring voltage, electric energy and protective relaying in the electric system with the frequency 50Hz or 60Hz and highest ...
Description: Epoxy resin casting and fully enclosed construction, is used indoor for measuring voltage, electric energy and protective relaying in the electric system with the frequency 50Hz or 60Hz and highest...
Description: Epoxy resin casting and fully enclosed construction, is used indoor for measuring voltage, electric energy and protective relaying in the electric system with the frequency 50Hz or 60Hz and highest...
Single phase current transformer small phase error mini PT voltage transformer Suitable for single-phase electricity meter as well as anti-tempering electricity meter Compact and delicate appearance Linea...
...Voltage DIN42531 20NF250 Transformer Bushing / OEM Description: DIN 42531 Height(mm) Creepage distance (mm) Power frequency withstand voltage(kV) Lightning impluse withstand voltage(kV) Weight(kg) 20NF250 38...
... through a partition such as transformer tank and insulating it, incorporating the means of attached flange to the partition for medium voltage level.The transformer sleeve is the main insulating device outs...
... One Year Input Voltage Customized Output Voltage Customized Ambient Temperature -15℃~+50℃ Cabinet Type Metallic Type Insulation Class Class F Insulation Resistance ≥2 MΩ Working ......