| Sign In | Join Free | My burrillandco.com |
|
...socket connections, and with and without moisture indicators. SG and SGR, without moisture indicator, are mainly used to indicate the condition of the refrigerant in the liquid line or the flow in the oil re...
...Danfoss Type Refrigeration Sight Glass SGN SGI 1/4'' 3/8'' Flare ext x ext SG is sight glasses for low pressure application (Max Working Pressure 500 psig). SG is available with flare, solder and socket conn...
... and socket connections, and with and without moisture indicators. SG and SGR, without moisture indicator, are mainly used to indicate the condition of the refrigerant in the liquid line or the flow in the o...
...air conditioning plant with HCFC. HFC and HC flammable refrigerants. The valves ensure the correct flow direction and prevent back-condensation from a warm part of the system to the cold evaporator. A built-...
...air conditioning plant with HCFC. HFC and HC flammable refrigerants. The valves ensure the correct flow direction and prevent back-condensation from a warm part of the system to the cold evaporator. A built-...
... For Danfoss Expansion Valve T2 / TE2 Orifice for expansion valve is used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant's superheat at the outlet of the evaporator....
...Danfoss TXV Thermal Expansion Valve T/TE 2 Orifice for expansion valve is used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant's superheat at the outlet of the evapor...
...Danfoss TXV Thermostatic Expansion Valve T2 / TE2 Orifice for expansion valve is used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant's superheat at the outlet of the...
...Danfoss TXV Thermal Expansion Valve T/TE 2 Orifice for expansion valve is used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant's superheat at the outlet of the evapor...
...Danfoss TXV Thermal Expansion Valve T2 / TE2 Orifice for expansion valve is used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant's superheat at the outlet of the evap...
... For Danfoss Thermal Expansion Valve T2/TE2 Orifice for expansion valve is used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant's superheat at the outlet of the evapo...
...liquid, suction and hot gas lines in refrigeration systems of food retail industry, in order to open and to shut off inner flow path by operating the valve spindle. The valves are specifically designed for ....
...Danfoss Type Crankcase Pressure Regulator Refrigeration CPR A CPR or Crankcase Pressure Regulator is nothing more than a pressure reducing valve. When installed on a compressor suction inlet and properly adj...
...Danfoss Type Condensing Pressure Regulator 1/2'' 034L0093 034L0096 Condensing pressure regulator is used to prevent the condensing temperature in a refrigeration system from dropping too low in a refrigerati...
...refrigeration system, especially during cold weather. They can be fitted in the hot-gas line downstream of the T-fitting branch to the receiver pressure regulator or in the condensate line. Technical Data: R...
...-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the...
...-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the...
...-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the...
...Danfoss Type Thermostatic Expansion Valve R134a R22 R407C R404A TGE is a dedicated designed series of thermostatic expansion valves for all standard refrigerants. The tight design meets the environmental dem...
... plant with HCFC. HFC and HC flammable refrigerants. The valves ensure the correct flow direction and prevent back-condensation from a warm part of the system to the cold evaporator. A built-in damping pisto...