... 60 Hz Noise level(7m) 56dB(A) Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C ...
...Diesel Generator Set , 15KVA 12KW 50Hz PERKINS Diesel Engine Model 403A-15G2 Generator set Genset Model SP15M5 Standby power 17KVA/13KW Rated power 15KVA/12KW Output voltage 230v/400v Frequency 50 Hz Noise l...
... 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humi...
... 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humi...
... 50 Hz Noise level(7m) 64 Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 2.6L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heater is needed when...
... 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humi...
... Frequency 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is belo...
... 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humi...
... Frequency 50 Hz Noise level(7m) 59.3dBA Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 6.2L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heater...
...Diesel Generator Set , 22KVA/18KW 50Hz PERKINS Diesel Engine Model404D-15G Generator set Genset Model SP22M5 Standby power 24KVA/19KW Rated power 22KVA/18KW Output voltage 230v/400v Frequency 50 Hz Noise lev...
...Diesel Generator Set ,27KVA/22KW 50Hz PERKINS Diesel Engine Model 404D-22TG Generator set Genset Model SP27M5 Standby power 30KVA/24KW Rated power 27KVA/22KW Output voltage 230v/400v Frequency 50 Hz Noise le...
...Diesel Generator Set ,33KVA/26KW 50Hz PERKINS Diesel Engine Model 404D-22G Generator set Genset Model SP33M5 Standby power 36KVA/29KW Rated power 33KVA/26KW Output voltage 230v/400v Frequency 50 Hz Noise lev...
... 50 Hz Noise level(7m) 72.1dB(A) Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 13.2L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heater is nee...
... Hz Noise level(7m) 69.8dB(A)/59.2dB(A) Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 18.7L/h (100%Load) Ambient temperature -25°C to 45°C. The coolant heater...
...400v Frequency 50 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 21.4L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heate...
...Diesel Generator Set ,113KVA/90KW 60Hz PERKINS Diesel Engine Model 1104C-44TAG2 Generator set Genset Model SP113E6 Standby power 123.75KVA/99KW Rated power 113KVA/90KW Output voltage 230v/400v Frequency 60 H...
... 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 50°C. The coolant heater is needed when the temperature is below 5°C Humi...
...Diesel Generator Set , 245KVA/196KW 60Hz PERKINS Diesel Engine Model 1506A-E88TAG1 Generator set Genset Model SP245M6 Standby power 269KVA/215KW Rated power 245KVA/196KW Output voltage 230v/400v Frequency 60...
... Frequency 50 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 30.28L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heater i...
...Diesel Generator Set , 281KVA/225KW 60Hz PERKINS Diesel Engine Model 1506A-E88TAG3 Generator set Genset Model SP400M6 Standby power 440KVA/352KW Rated power 400KVA/320KW Output voltage 230v/400v Frequency 60...