| Sign In | Join Free | My burrillandco.com |
|
...current transformer Winding Coil Current Transformer CT for Energy Measuring Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-886 Max. Current 10~600 A Turns Ratio 1:1000/2500/50...
... Ratio 1:2500/5000/10000/25000 Primary Current 10 A Secondary Current 0.4/1/2/4 mA Burden (Rb) 5~100 Ω Accuracy Class 0.05/0.1 Class DC Immunity Error <3% Busbar Type as required Mounting Method as required Accept Customized Yes Product Description 1....
...current transformer Low Voltage Current Transformer for Ring Coil 600A Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-881 Max. Current 10~600 A Turns Ratio 1:1000/2500/5000/1000...
...current transformer Metal Shield Current Transformer for Anti-Magnetic Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-877 Max. Current 10~600 A Turns Ratio 1:1000/2500/5000/1000...
... 1:1000/2500/5000/10000/25000 Primary Current 10 A Secondary Current 1/2/4/10 mA Burden (Rb) 5~100 Ω Accuracy Class 0.05/0.1/0.2 Class DC Immunity Error <3% Busbar Type as required Mounting Method as required Accept Customized Yes Product Description 1....
...current transformer Technical Support PCB Mount Current Transformer 150A Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-875 Max. Current 10~200 A Turns Ratio 1:1000/2000/2500 Pr...
... Ratio 1:1000/2500/5000/10000 Primary Current 10 A Secondary Current 1/2/4/10 mA Burden (Rb) 5~100 Ω Accuracy Class 0.1/0.2/0.5 Class DC Immunity Error <3% Busbar Type as required Mounting Method as required Accept Customized Yes Product Description 1....
Single Phase Split Core Current Transformer CT Clamps For Protection Measurement 1.Product Description A Split Core Current Transformer is a specialized type of current - measuring device that stands out for it...
... or three phase power system with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV Basic technical data: 1. Installation: outdoor 2. Insulation type: dry, epoxy cast 3. Highest voltage for...
...Transformer Type dry type Rated capacity up to 8000kva Rated voltage up to 11kv Frequency 50/60Hz Phase 3 Phase Winding material Copper /Aluminum Insulation class H(180℃), C (220℃) Vector group Dyn11, YNd1d1...
36kV Medium Current Transformer Outdoor Single-Phase Epoxy Resin Type 1.Product Introduction: Adopts outdoor epoxy resin casting and belongs to support type full-closed structure. The product can be made four s...
500A 50/60Hz Open type Split Core Current Transformer Smart Logger 1. Product Introduction: This type CT is designed for easy installation in tight spaces and environment without removing the main busbar or cab...
500A 50/60Hz Open type Split Core Current Transformer Smart Logger 1. Product Introduction: This type CT is designed for easy installation in tight spaces and environment without removing the main busbar or cab...