| Sign In | Join Free | My burrillandco.com |
|
...AC motor frequently, switching on and off the circuit at a long distance. It is used in combination with thermal relay to compose a magnetic motor starter. Standard: IEC 60947-1, IEC 60947-4-1. Rated operati...
... connected cables is special designed and manufactured as per IEC 60947-5-2: 2007 Annex C.8. It is used to test the structural strength performance of various proximity switches and photoelectric sensors wit...
..., Annex M21.203, Annex M21.301, figure M.301, IEC60745-2-5:2003 Annex BB.20.102, EN 60745-2-5:2010 clause 17.101 and clause 19.102.3. It is used to test the circular saw switch performance and circular saw l...
General dataSIL (SIL CL) up to: Performance Level (PL) up to: Safety category up to: Interlock, no contact, coded: Coding level:Safety parameter B o' Mission time: Ambient temperature. Ambient temp. with flexib...
... Product Line: Catalyst Product Series: 3750 Product Model: 3750G-12S Product Name: Catalyst 3750G-12S Ethernet Switch Product Type: Ethernet Switch Interfaces/Ports Port/Expansion Slot Details: 12 x...
... end Captive screw clamp terminals, >= 1 x 0.5 mm² Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947...
...…70 °C Overvoltage category Class I conforming to IEC 61140 IP degree of protection IP54 conforming to IEC 60529 Standards EN/IEC 60947-5-1 CSA C22.2 No 14 UL 508 Product certifications UL CSA RRS CCC Contac...
...) 690V AC (3-phase) Control Voltage 24V AC/DC Breaking Capacity (Icu) 100kA at 400V AC (per IEC 60947-2) Coil Power Consumption 5.5W (at 24V DC) Weight 1.8 kg Mounting DIN rail (EN 50022)...
... as other AC loads, such as solenoids, capacitors, lighting loads, heating loads and transformer loads. Standards: Contactors conform to IS/IEC 60947-4-1. They also carry the CE mark. Coordinated feeder: Con...
...load switching applications. It may function as a main contact module for high-current loads (e.g., motors, heaters) or as an auxiliary contact module for signal expansion in control circuits. Complies with ...
...load switching applications. It may function as a main contact module for high-current loads (e.g., motors, heaters) or an auxiliary contact module for signal expansion in control circuits. Complies with int...
... bimetal Contact type snap-action contact Contact resistance < 10mO Service life > 100 000 cycles Max. switching capacity 250VAC, 10 (2) A ,120VAC, 15 (2) A DC 30W EMC acc. to EN 55014-1-2, EN 61000-3-2, EN ...
... bimetal Contact type snap-action contact Contact resistance < 10mO Service life > 100 000 cycles Max. switching capacity 250VAC, 10 (2) A ,120VAC, 15 (2) A DC 30W EMC acc. to EN 55014-1-2, EN 61000-3-2, EN ...
...EN 50041 Cable entry M20 x 1.5 Electrical connection values Connection cross section 0.34 ... 1.5 mm² Rated insulation voltage Ui 250 V Rated impulse withstand voltage Uimp 2.5 kV Utilization category AC-1...
...-free magnetic detent mechanism * 2 pushbuttons, 2-stage, 1 NO contact each, e.g. for enabling function * Tamper-proof EMERGENCY STOP device according to EN ISO 13850, dual-channel * 2 selector switches,...
...Switch Products Overview with safety certifications UL 60950-1 CAN/CSA-C222.2 No. 60950-1 EN 60950-1 IEC 60950-1 AS/NZS 60950.1 IEEE 802.3 and Electromagnetic emissions certifications 47 CFR Part 15 CISPR22 ...
CM1 Molded Case Circuit Breaker 2, 3, 4 Pole 10~630A 380V 415V Icu up to 50kA in compliance with IEC 60947 characteristic As the main switch of the mechanical equipment Rated current: full range 15~630A Voltage...
... Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) 2.5 x 10-9 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Functions Restart ...
...Switch And Lower Guard Standard: IEC60745-2-5 ‘Hand-held motor-operated electric tools - Safety - Part 2-5: Particular requirements for circular saws’.2003 Annex BB.20.102. EN 60745-2-5: 2010 clause 17.101 a...
...switch Interfaces Inputs 4 safety inputs 4 switching inputs Number of muting sensors 0 / 2 Outputs 4 safety outputs 2 test outputs Delay time (outputs Q3/Q4) 0 s ... 5 s Connection type Plug-in spring termin...