| Sign In | Join Free | My burrillandco.com |
|
...EPOXY Coated Stainless Steel 304 Pilot Operated Water Pressure Sustaining Relief Valve Description: A500 is a hydraulically operated, pilot-controlled, modulating valve designed to maintain constant upstre...
... 3.Reduce a higher inlet pressure to a stable outlet pressure 4.Regardless of variation of inlet pressure or variation of outlet flow. 6.When downstream pressure exceeds setting, pilot and main valve will cl...
...Pressure Management Valve Dual Adjustable Set Point Pressure Based On Time Ductile Iron EPOXY Coated Description: In city with DMA management, water company can use Pressure Management Valve to control the p...
Intelligent Pressure Management Valve Dynamically Change Water Flow Regulator Description: P26 series is an intelligent pressure management valve. P26D can change the outlet pressure based on real time flow rat...
... using the vacuum epoxy resin casting process. This process involves encapsulating the transformer windings and core in epoxy resin under vacuum conditions, which provides electrical insulation and protectio...
...control the pressure of each single isolated DMA and decrease the leakage without swapping the broken pipes. In such operation, water authority can decrease the leakage rate and NRW - ......
Pressure Management Valve Based On Flow Rate Dynamically Change Pressure Ductile Iron EPOXY Coated Description: P26 series is a pressure management valve 1. P26D can change the outlet pressure based on real ti...
9Non Revenue Water Pressure Management Valve Dual Adjustable Set Point Pressure Based On Time Ductile Iron EPOXY Coated Description: In city with DMA management, water company can use Pressure Management Valve ...
... excessive pressure from the network. When the pressure returns to normal, the valve will close slowly, at an adjustable speed. The valve can also maintain upstream pressure, regardless of flow rate variatio...
... valve that is diaphragm actuated. It can fulfill either of two separate functions. When installed in-line, the valve sustains minimum pre-set, upstream (back) pressure regardless of fluctuating flow or vary...
... pressure, regardless of upstream pressure or flow rate fluctuation. The main valve is controlled by a 2-way pilot valve (creating a minimal differential in open position) to control the water in upper chamb...
... excessive pressure from the network. When the pressure returns to normal, the valve will close slowly, at an adjustable speed. The valve can also maintain upstream pressure, regardless of flow rate variatio...
... -- Nominal pressure 350 bar -- Maximum pressure 400 bar Features Fixed pump in axial piston swashplate design for hydrostatic drives in an open circuit For use in mobile and stationary applications Flow is ...
Stainless Steel Liquid/Fuel/Water Capacitive Level Transmitter/Capacitance Level Sensor Product Description NH-93420 high temperature liquid level transmitter consists of stainless steel gas collector, stainles...
...Pressure reducing valve EPOXY Coated Ductile Iron Main Valve SS304 Pilot Description: A200 keeps a preset downstream pressure, regardless of upstream pressure or flow rate fluctuation. The main valve is con...
...EPOXY Coated Ductile Iron Main Valve Description: A200 continuously maintains the constant downstream pressure with an accurcy of ± 5%. If there is no consumption, the valve is 100% drop-tight (clean water ...
...EPOXY Coated A200 Water Pressure Reducing Valve Ductile Iron Main Valve SS304 Pilot Description: A200 maintains a preset downstream pressure, regardless of upstream pressure or flow rate fluctuation. The mai...
... accurcy of ± 5%. If there is no consumption, the valve is 100% drop-tight (clean water provided). The downstream pressure will rise by approx. less than 0.5 bar under conditions between minimum an zero cons...
... may only have to operate intermittently to prevent pressure surges that might occur on pump start, pump stop, or sudden downstream valve closure. When A500 Installed in the main flow line,it acts as a backp...
... valve may only have to operate intermittently to prevent pressure surges that might occur on pump start, pump stop, or sudden downstream valve closure. When A500 Installed in the main flow line,it acts as a...