| Sign In | Join Free | My burrillandco.com |
|
Conventional fire project alarm 2 wire systems heat detector sensors They work perfectly with all conventional fire control panels Dual LEDs for 360-degree visibility Advanced MCU Expert Algorithm Software. Eas...
Conventional fire alarm 2 wire DC24V systems heat detector sensors They work perfectly with all conventional fire control panels Dual LEDs for 360-degree visibility Advanced MCU Expert Algorithm Software. Easy ...
Electric DC 24V conventional fire alarm 2 wire systems heat detector sensors They work perfectly with all conventional fire control panels Dual LEDs for 360-degree visibility Advanced MCU Expert Algorithm Softw...
Electric 24V 2 wire conventional fire alarm systems heat detector sensor They work perfectly with all conventional fire control panels Dual LEDs for 360-degree visibility Advanced MCU Expert Algorithm Software....
Conventional fire alarm systems heat detector sensor They work perfectly with all conventional fire control panels Dual LEDs for 360-degree visibility Advanced MCU Expert Algorithm Software. Easy installation a...
... 4 zones conventional fire alarm systems control panel This 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices. The panel accepts water flow devices, two-wire smoke dete...
... conventional fire alarm systems 24VDC control panel This 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices. The panel accepts water flow devices, two-wire smoke detect...
... conventional 24V fire alarm systems control panel This 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices. The panel accepts water flow devices, two-wire smoke detector...
Overcoating Flame Detector Tester , Mechanical Property Fire Extinguisher Testing Scope of application: It is applicable to the strength of adhesion, elongation and breaking strength of fire hose lining. Meet t...
1.2m High Sample Fire Equipment Testing , ZY6508 - 1.2 M Flame Detector Tester Scope of application: 1. The stiffness test (150N m moment) for fire hose reel plug box 2. The stiffness test (40N m moment) for ...
Model Number TX6701 Fire Detection and Alarm Systems Specifications Operating Voltage 20 V to 28 V DC Current Parameters Standby:23mA Commission:40mA Alarm:33mA Beam Sensor Sensitivity Level 1: 2.6 dB High Sens...
Model Number TX6701 Fire Detection and Alarm Systems Specifications Operating Voltage 20 V to 28 V DC Current Parameters Standby:23mA Commission:40mA Alarm:33mA Beam Sensor Sensitivity Level 1: 2.6 dB High Sens...
Model Number TX6701 Fire Detection and Alarm Systems Specifications Operating Voltage 20 V to 28 V DC Current Parameters Standby:23mA Commission:40mA Alarm:33mA Beam Sensor Sensitivity Level 1: 2.6 dB High Sens...
Model Number TX6701 Fire Detection and Alarm Systems Specifications Operating Voltage 20 V to 28 V DC Current Parameters Standby:23mA Commission:40mA Alarm:33mA Beam Sensor Sensitivity Level 1: 2.6 dB High Sens...
Soft Seated Wedge FM/UL Approved Gate Valve For Fire Fighting Service 300 PSI Soft Seated Wedge FM/UL Approved Gate Valve For Fire Fighting Service Features: 1. Stem Seal and Replacement : The valve has a stem ...
Firefighting Pumps On 450GPM @ 200PSI Centrifugal End Suction Fire Pumps By UL Listed Design Features according to UL / FM : All interior bolt or screw that are exposed to pumped liquid shall be of rolled bronz...
NFPA20 Standard Mutil-stage Vertial Turbine Fire Pump Capacities Up To 10,000 GPM For Firefighting Use Standard and Range Standards NFPA20, UL, EN12845,CCCF Performance Ranges UL : Q: 250-5000GPM H:80-300PSI FM...
UL Listed 1000 GPM Electric Motor Driven Fire Pump Set Split Case Type Pump Data Sheet: Pump Performance Curve: All NMFIRE pump sets are equipped with UL-listed flexible couplings....
UL/FM Listed Diesel Engine Drive Fire Pump With 1000gpm @ 70m Horizontal Split case Pump Pump: Split Case Pump Model: SCF150-100-320(UL/FM) Q= 1000usgpm H=70m n=2980rpm Material: Casing---Ductile Cast iron Impe...
... (8x6") 1800 (60Hz) 286 213.1 NM6-128 472 352 Performance Ranges: UL: Q: 500-4000GPM H:100-190PSI FM: Q: 500-4000GPM H:100-190PSI CCCF: Q:20-500L/S H:0.42-2.0Mpa NFPA20: Q: ......