Conductor Specification (AWG) 28 Section Area (mm) 0.0887 Material Tinned stranded copper Configuration (mm) TS7/0.1270.007 Insulation Ave Thickness (mm) 0.24 Min Thickness (mm) 0.20 Over Diameter (mm) 0.90...
Conductor Specification (AWG) 24 Section Area (mm) 0.2199 Material Tinned stranded copper Configuration (mm) TS7/0.200.007 Insulation Ave Thickness (mm) 0.32 Min Thickness (mm) 0.27 Over Diameter (mm) 1.30...
Conductor Specification (AWG) 30 Section Area (mm) 0.055 Material Tinned stranded copper Configuration (mm) TS7/0.100.007 Insulation Ave Thickness (mm) 0.23 Min Thickness (mm) 0.19 Over Diameter (mm) 0.800...
Conductor Specification (AWG) 28 Section Area (mm) 0.0887 Material Tinned stranded copper Configuration (mm) TS7/0.1270.007 Insulation Ave Thickness (mm) 0.24 Min Thickness (mm) 0.21 Over Diameter (mm) 0.90...
Conductor Specification (AWG) 28 Section Area (mm) 0.0887 Material Tinned stranded copper Configuration (mm) TS7/0.1270.007 Pitch Distance (mm) 2.0 Ave Thickness (mm) 0.24 Min Thickness (mm) 0.21 Over Dia...
Conductor Specification (AWG) 28 Section Area (mm) 0.0887 Material Top Coated Copper Configuration (mm) TC7/0.1270.007 Insulation Pitch Distance (mm) 2.54 Ave Thickness (mm) 0.24 Min Thickness (mm) 0.21 Ove...
Conductor Specification (AWG) 28 Section Area (mm) 0.0887 Material Tinned stranded copper Configuration (mm) TS7/0.1270.007 Insulation Pitch Distance (mm) 2.54 Ave Thickness (mm) 0.24 Min Thickness (mm) 0.2...
Conductor Specification (AWG) 28 Section Area (mm) 0.0887 Material Tinned stranded copper Configuration (mm) TS7/0.1270.007 Insulation Pitch Distance (mm) 3.96 Ave Thickness (mm) 0.24 Min Thickness (mm) 0.2...
Conductor Specification (AWG) 26 Section Area (mm) 0.1407 Material Tinned stranded copper Configuration (mm) TS7/0.160.007 Insulation Pitch Distance (mm) 1.00 Ave Thickness (mm) 0.23 Min Thickness (mm) 0.20...
Conductor Specification (AWG) 24 Section Area (mm) 0.2199 Material Tinned stranded copper Configuration (mm) TS7/0.200.007 Insulation Pitch Distance (mm) 1.30 Ave Thickness (mm) 0.32 Min Thickness (mm) 0.27...
Conductor Specification (AWG) 24 Section Area (mm) 0.2199 Material Tinned stranded copper Configuration (mm) TS7/0.200.007 Insulation Pitch Distance (mm) 2.00 Ave Thickness (mm) 0.32 Min Thickness (mm) 0.27...
Conductor Specification (AWG) 24 Section Area (mm) 0.2199 Material Tinned stranded copper Configuration (mm) TS7/0.200.007 Insulation Pitch Distance (mm) 3.96 Ave Thickness (mm) 0.32 Min Thickness (mm) 0.27...
Conductor Specification (AWG) 30 Section Area (mm) 0.055 Material Tinned stranded copper Configuration (mm) TS7/0.100.007 Insulation Pitch Distance (mm) 1.27 Ave Thickness (mm) 0.23 Min Thickness (mm) 0.19 ...
Conductor Specification (AWG) 30 Section Area (mm) 0.055 Material Tinned stranded copper Configuration (mm) TS7/0.100.007 Insulation Pitch Distance (mm) 1.00 Ave Thickness (mm) 0.23 Min Thickness (mm) 0.19 ...
Conductor Specification (AWG) 26 Section Area (mm) 0.1407 Material Tinned stranded copper Configuration (mm) TS7/0.160.007 Insulation Pitch Distance (mm) 2.54 Ave Thickness (mm) 0.43 Min Thickness (mm) 0.37...
Conductor Specification (AWG) 26 Section Area (mm) 0.1407 Material Tinned stranded copper Configuration (mm) TS7/0.160.007 Insulation Pitch Distance (mm) 2.00 Ave Thickness (mm) 0.43 Min Thickness (mm) 0.37...
Conductor Specification (AWG) 26 Section Area (mm) 0.1407 Material Tinned stranded copper Configuration (mm) TS7/0.160.007 Insulation Pitch Distance (mm) 3.96 Ave Thickness (mm) 0.43 Min Thickness (mm) 0.37...
Conductor Specification (AWG) 24 Section Area (mm) 0.2199 Material Tinned stranded copper Configuration (mm) TS7/0.200.007 Insulation Pitch Distance (mm) 2.54 Ave Thickness (mm) 0.42 Min Thickness (mm) 0.35...
Conductor Specification (AWG) 24 Section Area (mm) 0.2199 Material Tinned stranded copper Configuration (mm) TS7/0.200.007 Insulation Pitch Distance (mm) 2.00 Ave Thickness (mm) 0.42 Min Thickness (mm) 0.35...
Conductor Specification (AWG) 24 Section Area (mm) 0.2199 Material Tinned stranded copper Configuration (mm) TS7/0.200.007 Insulation Pitch Distance (mm) 3.96 Ave Thickness (mm) 0.42 Min Thickness (mm) 0.35...