| Sign In | Join Free | My burrillandco.com |
|
...: to check the maximum dimensions of the screw thread and dimension T1 minimum of E40 caps on finished lamps. Testing: when the cap on a finished lamp has been screwed into the gauge as far as it will go, th...
...cap gauge | Gauge for finished lamps fitted with E14 caps for testing contact making | 7006-54-2 Purpose: to check lamp dimensions for contact making in IEC holders. Testing: the shape of the lamp with regar...
...cap gauge | Gauge for finished lamps fitted with E14 caps for testing protection against accidental contact E14-7006-55-2 Purpose: to check protection against accidental contact. Testing: the shape of the la...
...been pushed into the gauge as far as it will go, surface W of the plunger shall not project beyond surface X. For caps on finished lamps, surface W shall not project beyond surface V. In this instance, the c...
... Lampholders. TESTING: The shape of the lamp with regard to the fit in the lampholder is assumed to be correct, if the lamp can be pushed into the gauge until plane W reaches plane V or projects beyond it. F...
...finished lamps. Testing: caps on finished lamps shall be assured to be correct if the gauge does not pass over the cap by its own weight. “Go” Gauges for B22 Caps on Finished Lamps(7006-11-8) Purpose: to che...
...cap gauge | "GO" and "NOT GO" Gauge For Caps GX53 | 7006-142-1 PURPOSE: To check caps GX53-.. in the following respects: - the diameter of the individual pins (dimension A); - the combine...
7006-52-1 Lamp cap gauge for finished lamps fitted with E40 caps for testing contact making Standard E40 Lamp cap gauge 7006-52-1 gauge for finished lamps fitted with E40 caps for testing contact making IEC6006...
...Cap Gauge Go Gauge 7006 - 45 and No Go Gauge 7006 - 44 “Go” Gauge for Bi-pin Cap G13 on Finished Lamps (7006-45-4) Purpose: to check dimensions E max,, F min, F max, and the combined pin diameter and displac...
...dimension T1 minimum of caps on finished lamps shown on sheet 7004-21. Testing: When the cap on a finished lamp has been screwed into the gauge as far as it will go, the center contact shall be co-planar wit...
... for contact making in IEC holders. Testing: the shape of the lamp with regard to the fit in the lampholder is assumed to be correct, if the lamp can be pushed into the gauge till plane W reaches plane V or ...
...cap gauge | Not go gauges for screw threads of lampholders E40 | 7006-26-4 Purpose: to check the maximum minor diameter of the screw thread, dimesion D1, of lampholder E40. Testing: the screw thread of the l...
...E12 "Not Go"gauges for E12 caps on finished lamps SC-E12C3 IEC60061-3,7006-27J-1 E12 Additional "Go" gauge for caps on finished lamps E12 SC-E12C4 IEC60061-3,7006-32-1 E12 Gauge for finished lamps fitted wit...
...Cap Gauge Go No Go Gauge For Testing Contact - Making Of Lamps Fitted With Caps Confirms: IEC60061-3 Gauge name and Testing Purpose 1. E26, E26/50x39, E26/51x39 & E26d “NOT GO” GAUGE FOR CAPS 7006-29L-4 TES...
...E12 "Not Go"gauges for E12 caps on finished lamps SC-E12C3 IEC60061-3,7006-27J-1 E12 Additional "Go" gauge for caps on finished lamps E12 SC-E12C4 IEC60061-3,7006-32-1 E12 Gauge for finished lamps fitted wit...
...Cap Gauge Go No Go Gauge For Testing Contact - Making Of Lamps Fitted With Caps Confirms: IEC60061-3 Gauge name and Testing Purpose 1. E26, E26/50x39, E26/51x39 & E26d “NOT GO” GAUGE FOR CAPS 7006-29L-4 TES...
...cap gauge | Go gauges for screw threads of lampholders E40 | 7006-25-7 Purpose: to check the minimum dimensions of the lampholder screw thread and dimension X shown on the sheet 7006-20. Testing: it shall be...
...cap gauge | Plug gauge for lampholders for testing protection against accidental contact E40 | 7006-24-3 Purpose: to check the E40 lampholders in respect of protection against accidental contact. Testing: th...
...cap gauge | Gauge for testing protection against bulb-neck damage and for testing contact-making in lampholders E40-7006-23-3 Purpose: to check the maximum minor diameter of the screw thread, dimesion D1, of...
...Cap Gauge Bi Pin Go No Go Pin Gauge On Finished Lamps T8 G13 Gauge list: IEC60061-3,7006-45-4 G13(T8) Go gauge for bi-pin cap on finished lamps IEC60061-3,7006-44-5 G13(T8) Go and not go gauge for unmounted ...