| Sign In | Join Free | My burrillandco.com |
|
...current transformer 3.3mA robbery Iron casing shielding with busbar Suitable for high precision, small phase error requirments of three-phase electric energy meters More space in the meter can be saved w...
...current transformer 4-20ma ZCT Zero Phase Current Transformer Rated current : 30A Rated Output :10~12.5 mV Operating frequncy : 50Hz/60Hz Dielectric withstanding voltage(Hi-pot): 2500Vrms (between outside/se...
...current transformer 4-20ma ZCT Zero Phase Current Transformer Rated current : 30A Rated Output :10~12.5 mV Operating frequncy : 50Hz/60Hz Dielectric withstanding voltage(Hi-pot): 2500Vrms (between outside/se...
...current transforme 30A small zero Adhesive tape current transformer for Residual current circuit breaker circuit electronic sensor : Features: Minimum output voltage tolerance Close to zero load shift and ze...
...current transforme 15A PCB Layout Current Transformer 1.5~2.0V PIN type Item No. :WSD-ZCT528 Rated current : 15A Rated Output :1.5~2.0V Operating frequncy : 50Hz/60Hz Dielectric withstanding voltage(Hi-pot):...
...current transformer Ultra-Micro PCB Mounting Current Transformer Features and applications: Small size,high accuracy,good consistency,for current and power measurement Structural parameters: Remarks: Primary...
...Current Transformer For Energy Meter 1.Main Features: ● 100A Split Core Current Transformer ● High Reliability via High Accuracy ● Easy Assembly,"0" Cost "0" Destroy ● Well-matched to Measuring & Control Uni...
...Current Split Core Current Transformer 1.Main Features: ● 500A Split Core Current Transformer ● High Reliability via High Accuracy ● Easy Assembly,"0" Cost "0" Destroy ● Well-matched to Measuring & Control U...
...Measuring ● Flexible Installation 2. Technical Parameters: Main Parameter Primary Current 10(100)A/10(60)A Secondary Current 4mA Class Accuracy 0.1 Wire Length 10cm/12cm(customized) Installation Flexible Ins...
...Current Transformer 1.Overview: ● 100A Split Core Current Transformer ● High Reliability via High Accuracy ● Easy Assembly,"0" Cost "0" Destroy ● Well-matched to Measuring & Control Unit ● Widely used for en...
...Current Transformer and PT Potential Current Testing Equipment is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current...
....5kv 4.accuracy class: 0.2 , 0.5 , 1 , 10P , 5P10 5.Burden :from 30VA to 100VA 6.Rated primary curent : 5A to 1000A 7.Rated secondary current :5A or 1A 8.Rated insulation level : 36/70/170kv ; 40.5/80/200kv ...
... or bus-bar circuit. An internal precision resistor across the secondary winding of the CT provides a low safe voltage output. Apply to current measurement, monitoring and protection for...
Split Core Current Transformer AKH-0.66/K-φ24 ● Measurement: Alternating Current (AC) ● Accuracy: Class 0.5 ● Primary Current Input: 60~400A AC ● Rated Voltage: 660V AC ● Rated Frequency: 50~60Hz ● Installtion:...
...Current Transformer LZCG530-10 Epoxy Resin Cast CT LZCK series resin split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC...
...Current Transformer and Potential Transformer Meter CT 1.Overview: ● DC Immunity with Better Phase Error ● Tooled Casing Instead of Traditional Tape ● Irregular Central Hole for Easy Assembly ● Various Busba...
Split Core Current Transformer Clamp On Type The HM-CTC1535 is a high performance AC clamp on Current transformer with excellent transformation and low phase shift. The high quality magnetic core and uniform wi...
0.1A-1000A 0.05 Class AC Clamp on Split Core Current Transformers for Monitoring The HM-CTC1535 is a high performance AC clamp on Current transformer with excellent transformation and low phase shift. The high ...
... up to Class 0.5 ,foot or Busbar mounted switchgear Energy Management Systems Instrumentation Equipment. Split Core Current Transformers are designed for assembly to an existing electrical installation no ne...