| Sign In | Join Free | My burrillandco.com |
|
... Package Hall Effect Based Linear Current Current - Sensing 6A Number of Channels 1 Output Ratiometric, Voltage Sensitivity 151mV/A Frequency DC ~ 120kHz Linearity ±0.25% Accuracy ±1.6% Voltage - Supply 3V ~...
... Hall Effect-Based Linear Current Sensor Transducer Current - Sensing 12.5A Number of Channels 1 Output Ratiometric, Voltage Sensitivity 110mV/A Frequency DC ~ 100kHz Linearity ±1% Accuracy ±5% Voltage - Sup...
... Hall Effect-Based Linear Current Sensor Transducer Current - Sensing 25A Number of Channels 1 Output Ratiometric, Voltage Sensitivity 55mV/A Frequency DC ~ 100kHz Linearity ±1% Accuracy ±5% Voltage - Supply...
... Hall Effect-Based Linear Current Sensor Transducer Current - Sensing 30A Number of Channels 1 Output Ratiometric, Voltage Sensitivity 133mV/A Frequency DC ~ 80kHz Linearity ±1.5% Accuracy ±1.5% Voltage - Su...
...-PowerWFQFN Hall Effect-Based Linear Current Wide Dynamic Range Current - Sensing 10A Number of Channels 1 Output Voltage Sensitivity 132mV/A Frequency 120kHz Linearity ±1% Accuracy ±6% Voltage - Supply 3V ~...
...Hall Effect-Based Linear ACS Current Sensor Transducer with 8-SOIC Package Current - Sensing 30A Number of Channels 1 Output Ratiometric, Voltage Sensitivity 133mV/A Frequency DC ~ 80kHz Linearity ±1.5% Accu...
...Hall Effect-Based Linear Current Sensor Transducer with ±20A Operating Range Current - Sensing 20A Number of Channels 1 Output Ratiometric, Voltage Sensitivity 100mV/A Frequency 1MHz Linearity ±0.75% Accurac...
... Transducers Hall Effect-Based Linear Current 8-SOIC Package Current - Sensing 10A Number of Channels 1 Output Voltage Sensitivity 132mV/A Frequency 120kHz Linearity ±1% Accuracy ±6% Voltage - Supply 3V ~ 3....
...SOIC Package Hall Effect Based Linear Current Current - Sensing 50A Number of Channels 1 Output Ratiometric, Voltage Sensitivity 40mV/A Frequency 1MHz Linearity ±0.75% Accuracy ±3% Voltage - Supply 4.5V ~ 5....
...power aluminum bus bar on-line detection. In electrical and electronic engineering, a current clamp. current probe is an electrical device having jaws which open to allow clamping around an electrical conduc...
..., power quality analyzer. It can measure low currents 100A primary, and output current on 100mA secondary. Clamp sensor Q13-2 enables the user of a clamp meter to measure the current without having to cut of...
...Hall effect BLDC motor driver board MODEL:JYQD-V7.3E2 OPERATING VOLTAGE(V):24VDC MAX CURRENT (A):15A ANALOG VOLTAGE SPEED REGULATION (V):0-5V Speed pulse signal output:YES Application guidelines 1. Please c...
... engineering, a current clamp. current probe is an electrical device having jaws which open to allow clamping around an electrical conductor. This allows measurement of the current in a conductor without the...
... Current Probe clamp transformer MODEL Q8A-2 Characteristic :apply to test on line below 5A 10A Jaw:Φ8mm Size :45mm×158mm×25mm Load capacity: ≤4Ω Installation method:clamp type Output :down-lead output param...
... Current Probe clamp transformer MODEL Q8A-2 Characteristic :apply to test on line below 5A 10A Jaw:Φ8mm Size :45mm×158mm×25mm Load capacity: ≤4Ω Installation method:clamp type Output :down-lead output param...
...Current 3-Phase BLDC motor driver board for Hall effect BLDC Motor Specifications Operating Voltage DC 36V Operating current ≤20A Output power ≤700W Speed control 0.1V-5V or PWM input Operating temperature -...
Product Attribute Attribute Value Product Category: Board Mount Hall Effect / Magnetic Sensors Type: Hall Effect Switch Operating Supply Current: 7 mA Maximum Output Current: 10 mA Operating Point Min/Max: 5.2 ...
...: 3D Operating Supply Current: 3.6 mA Maximum Output Current: 3 mA Operating Point Min/Max: - 40 G to 40 G Release Point Min/Max (Brp): 5 G to - 5 G Operating Supply Voltage: 3.3 V ......
Product Attribute Attribute Value Product Category: Board Mount Hall Effect / Magnetic Sensors Type: Hall Effect Switch Operating Supply Current: 7 mA Maximum Output Current: 10 mA Operating Point Min/Max: 5.2 ...
...: 3D Operating Supply Current: 3.6 mA Maximum Output Current: 3 mA Operating Point Min/Max: - 40 G to 40 G Release Point Min/Max (Brp): 5 G to - 5 G Operating Supply Voltage: 3.3 V ......