| Sign In | Join Free | My burrillandco.com |
|
...: According to customer drawings Product Description 2. Electrical Test 2.1. Hi-Pot Test: DC300V. 2.2. Insulation Resistance: 5M Ohms (Min). 2.3. Contactor Resistance: 1 Ohms (Max). 2.4. 100% Open Short and ...
... 1.3 Specifications: According to customer drawings 2. Electrical Test 2.1. Hi-Pot Test: DC300V. 2.2. Insulation Resistance: 5M Ohms (Min). 2.3. Contactor Resistance: 1 Ohms (Max). 2.4. 100% Open Short and M...
...drawings 1.3 Specifications: According to customer drawings 2. Electrical Test 2.1. Hi-Pot Test: DC300V. 2.2. Insulation Resistance: 5M Ohms (Min). 2.3. Contactor Resistance: 1 Ohms (Max). 2.4. 100% Open Sho...
... to customer drawings Product Description 2. Electrical Test 2.1. Hi-Pot Test: DC300V. 2.2. Insulation Resistance: 5M Ohms (Min). 2.3. Contactor Resistance: 1 Ohms (Max). 2.4. 100% Open Short and Miss Wire T...
... to customer drawings Product Description 2. Electrical Test 2.1. Hi-Pot Test: DC300V. 2.2. Insulation Resistance: 5M Ohms (Min). 2.3. Contactor Resistance: 1 Ohms (Max). 2.4. 100% Open Short and Miss Wire T...
...: According to customer drawings 2. Electrical Test 2.1. Hi-Pot Test: DC300V. 2.2. Insulation Resistance: 5M Ohms (Min). 2.3. Contactor Resistance: 1 Ohms (Max). 2.4. 100% Open Short and Miss Wire Test. 3. A...
... 1.3 Specifications: According to customer drawings 2. Electrical Test 2.1. Hi-Pot Test: DC300V. 2.2. Insulation Resistance: 5M Ohms (Min). 2.3. Contactor Resistance: 1 Ohms (Max). 2.4. 100% Open Short and M...
... Color Any color available Temperature Rating Minus 40C though plus 75C Approvals VDE Environmental Certifications RoHS REACH Testing Hi-Pot (Dielectric Withstanding Voltage), Polarity (pinout) and Continuit...
..., beryllium and nickel. Brazing eliminates oxidation, outgassing and virtual leak areas that are common with welding. Other services such as helium leak and pressure testing, TIG and plasma arc welding, elec...
..., beryllium and nickel. Brazing eliminates oxidation, outgassing and virtual leak areas that are common with welding. Other services such as helium leak and pressure testing, TIG and plasma arc welding, elec...
Cord Flexibility Performance Tester Standard: This power cord flexibility performance tester conforms to Clause 23.3 and 25.14 of IEC 60335-1 Household and similar electrical appliances – Safety – Part 1: Gener...
...differential‑mode noise attenuation covering 150kHz‑30MHz under 50‑ohm test system. It features 0.3mA max leakage current @115VAC/60Hz and 0.6mA max @250VAC/50Hz. It passes 2000VAC line‑to‑ground and 1450VDC...
... Outer Diameter 0.35mm Contact Resistance ≤3Ω max Insulation Resistance ≥20MΩ (DC 200V) Voltage Rating AC 200V (Hi-pot tested) Quality...
... (Per UL1354) Temp. Range -40°C to +80°C (Operating) Conductor Resistance ≤3.0Ω (Max per Connector) Insulation Resistance ≥10MΩ (100V DC) Hi-Pot Test 100V AC, 0.5mA,...
... 105°C continuous Flame Rating UL VW-1 certified Conductor Resistance ≤3.0Ω max Insulation Resistance ≥20MΩ @200V DC Hi-Pot Test 200V...
... Type UL1571 28AWG (OD 0.6mm) Voltage Rating 300V Temperature Range -40°C to +80°C Contact Resistance ≤2 ohms Hi-Pot Test AC 200V/0.1s Insulation Resistance ≥20MΩ @200V DC...
... UL1571 28AWG (0.6mm OD) Length Customizable Insulation Resistance ≥10MΩ @100V DC Contact Resistance ≤20mΩ Max Hi-Pot Test AC 100V/0.1s Pass Compliance RoHS, UL1571...
... Type UL1354 36AWG (Red) Shielded Flat Flex Contact Resistance ≤5Ω Max Insulation Resistance ≥20MΩ @200V DC Hi-Pot Test AC 200V/0.1s Pass Voltage Rating 30V AC/DC Operating Temp -40°C to +80°C...
... Copper Electrical Hi-Pot Test: DC300V Insulation Resistance: 10M Ohms (Min) Contactor Resistance: 1 Ohms (Max) 100% Open Short and Miss Wire Test Mechanic Insertion Force: 45N Max Withdrawal Force: 15N Min ...
... Copper 6. Power Cable: UL1007/UL1061 18 / 20 AWG/22AWG, Tinned Copper Electrical 1. Hi-Pot Test: DC300V 2. Insulation Resistance: 10M Ohms (Min) 3. Contactor Resistance: 1 Ohms (Max) 4. 100% Open Short and ...