...Current Transformer, a reliable and efficient solution for measuring and monitoring current in low voltage systems. This product is designed with precision and accuracy in mind, providing users with a depend...
... clamping around an electrical conductor. This allows measurement of the current in a conductor without the need to make physical contact with it, or to disconnect it for insertion through the probe.GFUVE Mo...
...Current Transformer with PBT Anti-combustion Plastic Casing FEATURES: · All enclosed design, good performance of mechanical and insulation. · Pin design, easy to installate in PCB. · This series of CTs have ...
... Current Transformer FEATURES: · All enclosed design, good performance of mechanical and insulation. · Pin design, easy to installate in PCB. · This series of CTs have small size that can be used as separate...
...: 720V AC ● Test voltage: 3kV AC(1min) ● Rated frequency: 50/60Hz ● Rated short-time thermal current: Ith=40~60In ● Rated dynamic current: Idyn=2.5Ith ● Rated secondary current: X/5A (X/1A upon request) ●...
...current transformer Winding Coil Current Transformer CT for Energy Measuring Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-886 Max. Current 10~600 A Turns Ratio 1:1000/2500/50...
... Ratio 1:2500/5000/10000/25000 Primary Current 10 A Secondary Current 0.4/1/2/4 mA Burden (Rb) 5~100 Ω Accuracy Class 0.05/0.1 Class DC Immunity Error <3% Busbar Type as required Mounting Method as required Accept Customized Yes ......
...current transformer Low Voltage Current Transformer for Ring Coil 600A Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-881 Max. Current 10~600 A Turns Ratio 1:1000/2500/5000/1000...
...current transformer Reliable Round Type Current Transformer for KWH Meter Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-879 Max. Current 10~600 A Turns Ratio 1:1000/2500/5000/1...
...current transformer Metal Shield Current Transformer for Anti-Magnetic Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-877 Max. Current 10~600 A Turns Ratio 1:1000/2500/5000/1000...
... 1:1000/2500/5000/10000/25000 Primary Current 10 A Secondary Current 1/2/4/10 mA Burden (Rb) 5~100 Ω Accuracy Class 0.05/0.1/0.2 Class DC Immunity Error <3% Busbar Type as required Mounting Method as required Accept Customized Yes ......
...current transformer Technical Support PCB Mount Current Transformer 150A Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-875 Max. Current 10~200 A Turns Ratio 1:1000/2000/2500 Pr...