| Sign In | Join Free | My burrillandco.com |
|
... ● Withstand Voltage No Less Than 3KV 2.Technical Parameters: Basic Parameter Primary Current(A) Secondary Current(mA) Resistance Rb (Ω) Maximum Current(A) Class Frequency 1 0.5 10 10 0.1 50-60 Hz Class Curr...
...Current Transformer is a top-of-the-line product designed to meet the highest industry standards, including IEC 61869-1 & 2 (IEC 60044-1). This advanced transformer is also known as a Motor Voltage Current T...
#detail_decorate_root .magic-0{border-bottom-style:solid;border-bottom-color:#53647a;font-family:Roboto;font-size:24px;color:#53647a;font-style:normal;border-bottom-width:2px;padding-top:8px;padding-bottom:4px}...
...current transformer , class 0.5 class1.0 current transformer Specifications: CT Current Transformer: 1. Voltage: 0.5KV 2. Frequency:50Hz 3. Primary current: 5-1200A 4. Secondary current: 5A Production Descri...
...current transformer small phase error mini PT voltage transformer Suitable for single-phase electricity meter as well as anti-tempering electricity meter Compact and delicate appearance Linear output c...
0.5KV / 3KV DC Contactor Current Transformers , Accurate Low Voltage Protection Devices LMZJ1-0.5 Current Transformers Technical parameter Model Rated current ratio(A) Feed- through turns Accurate level and rat...
Window DC Contactor Low Voltage Protection Devices Current Transformers 0.66KV / 3KV LMZJ1-0.66 Current Transformers Technical parameter Model Rated current ratio(A) Bus bar Feed- through turns Accurate level a...
...protect the equipment. Technical Features Technical parameter ADL100-EY Voltage Reference voltage 3*220/380V Reference frequency 50Hz Consumption <4VA(Each phase) Current Input Current 1(6)A,10(80)A Starting Current Connect directly: 0.004 Ib, connect via...
...protect the equipment. Technical Features Technical parameter ADL100-EY Voltage Reference voltage 3*220/380V Reference frequency 50Hz Consumption <4VA(Each phase) Current Input Current 1(6)A,10(80)A Starting Current Connect directly: 0.004 Ib, connect via...
... is intended for power measurement, current monitoring and relay protection in the line of up to 35 kV and AC 50-60 Hz. The current transformer made from high temperature indoor epoxy resin, amorphous alloy ...
...current transformer 30A Zero Phase Current Sensor Low Cost Leakage Rated current : 30A Rated Output :3.5~4.2 mV Operating frequncy : 50Hz/60Hz Dielectric withstanding voltage(Hi-pot): 3000Vrms (between outsi...
... Frequency: 50 to 400 Hz Retardant rating: 94-V0 Isolation voltage: 2500 Vrms for 1 minute Dielectric resistance: 1, 000MΩ At 500V DC Surge withstand: 5000V (1.2/50μ S standard shock wave) ......
... Frequency: 50 to 400 Hz Retardant rating: 94-V0 Isolation voltage: 2500 Vrms for 1 minute Dielectric resistance: 1, 000MΩ At 500V DC Surge withstand: 5000V (1.2/50μ S standard shock wave) ......
..., versatility, and low phase shift to theprobe for a good selection of application range of power measurement widely. Current clamp is portable AC current measuring device and the one-hand operating solution...
...Transformer Protection Using High-Voltage Current-Limiting Fuse Product Description ELSP Current-Limiting Backup Fuse is used in series with low current primary protection devices such as a Bay-O-Net fuse or...
...designed to "step up" or "step down" voltages and works on the magnetic induction principle. A transformer has no moving parts and is a completely static solid state device, which insures, under normal opera...
High Efficiency Low Cost Wire EI16/19 Low Frequency Transformer for Audio 1.Product Description Functions of EI Low Frequency Transformer: 1.Voltage conversion --Boosting and bucking function: Low Frequency T...
..., rated voltage 7.2 kv-40.5 kv power systems, as a transformer and other power equipment overload or short-circuit protection components. And can be used with other protective electrical appliances (load swi...