| Sign In | Join Free | My burrillandco.com |
|
...High Voltage Generator Widely used in electricity power supply companies, power transmission and transformation engineering company and large industrial enterprises for preventive test and scientific researc...
...High Voltage Generator Widely used in electricity power supply companies, power transmission and transformation engineering company and large industrial enterprises for preventive test and scientific researc...
...h very-low frequency test frequency for power generators or 35KV and below XLPE power cable.Compared with Hipot test set at main power frequency, VLF HV Test Set just needs much small test power capacity(Abo...
...h very-low frequency test frequency for power generators or 35KV and below XLPE power cable.Compared with Hipot test set at main power frequency, VLF HV Test Set just needs much small test power capacity(Abo...
...Voltage Test Kit Voltage Breakdown Test Product Description XHYB-100 AC/DC hipot tester is make of two parts. one is test transformer, Another is operator instrument(a control box). This product was an combi...
...Voltage Test Set , For 35KV &10KV Cable Test , 30~300Hz Test Frequency I. Product Usage : This test set model FKTF-81KVA/27KV, 54KV is designed for 10KV / 35KV class XLPE cable ,power transformer, CB,CT/PT, ...
...Voltage Test Set , For 35KV &10KV Cable Test , 30~300Hz Test Frequency I. Product Usage : This test set model FKTF-81KVA/27KV, 54KV is designed for 10KV / 35KV class XLPE cable ,power transformer, CB,CT/PT, ...
... Cable fault location system Name QTY TDR 1 110kV Accessory Pin pointer 1 Cable route tracer 1 Power frequency withstand voltage test set High voltage trial transformer 1 Operation Box Pulse Storage Capacito...
... Cable fault location system Name QTY TDR 1 110kV Accessory Pin pointer 1 Cable route tracer 1 Power frequency withstand voltage test set High voltage trial transformer 1 Operation Box Pulse Storage Capacito...
...h very-low frequency test frequency for power generators or 35KV and below XLPE power cable.Compared with Hipot test set at main power frequency, VLF HV Test Set just needs much small test power capacity(Abo...
...h very-low frequency test frequency for power generators or 35KV and below XLPE power cable.Compared with Hipot test set at main power frequency, VLF HV Test Set just needs much small test power capacity(Abo...
.... Configuration Cable fault location system Name Model QTY TDR XHGG501C 1 Pin pointer XHDD503K 1 Cable route tracer XHGX507 1 High voltage generator XHHV532-4C 1 III. Main Technical data 1) Windows operating...
.... Configuration Cable fault location system Name Model QTY TDR XHGG501C 1 Pin pointer XHDD503K 1 Cable route tracer XHGX507 1 High voltage generator XHHV532-4C 1 III. Main Technical data 1) Windows operating...
...Test System JTKZ-1Kva/50kV System comprised of 1. Control Box 2. Test Transformer 3. Other all necessary accessories for completing the test Features and Technical Index Control Box (including voltage regul...
...Test System JTKZ-1Kva/50kV System comprised of 1. Control Box 2. Test Transformer 3. Other all necessary accessories for completing the test Features and Technical Index Control Box (including voltage regul...
... equipment of large capacitor and high voltage and can also satisfy field AC voltage withstand test of sorts of capacitance apparatus. HV test reactors use combined series-parallel patterns which not only me...
... equipment of large capacitor and high voltage and can also satisfy field AC voltage withstand test of sorts of capacitance apparatus. HV test reactors use combined series-parallel patterns which not only me...
..., it make series resonance happen between reactor induction L in circuit and test object capacitor C, resonance voltage is the voltage applied on test object. Widely used in power, metallurgy, petroleum, che...
..., it make series resonance happen between reactor induction L in circuit and test object capacitor C, resonance voltage is the voltage applied on test object. Widely used in power, metallurgy, petroleum, che...
... on-site AC hpot test and 362KV and below class GIS on-site AC hipot test with variable frequency resonant circuit technology; the highest test voltage is no more than 150KV,300KV,450KV through cylinder test...