| Sign In | Join Free | My burrillandco.com |
|
...IV Transformer Testing Equipment Load and No Load Power Analyzer (Table type) Product Description RSBTC-IV Power Analyzer is a high-accuracy instrument meticulously researched and developed by our company, e...
RSHL-200A CT PT Testing Equipment High Accuracy 0.05 class 200A Standard Current Transformer Product Description The function of the Current Transformer and Votage Transformer is to reduce the AC voltage and th...
...Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer Product Description Purpose The function of the transformer is to reduce the ac voltage and the large current in proportion to the...
... damp deterioration of electrical equipment insulation, as well as local defects. In electrical manufacturing, electrical equipment installation, transfer and preventive tests are widely used. Measuring diel...
... with IEC60044-1 / GB1208, IEC60044-2GB1207, IEC60044-6 / GB16847 and C57.13, the instrument can obtain excitation characteristic of current and voltage transformer, excitation parameters, turns ratio, turns...
...Transformer Insulating Oil Dielectric Loss Tester Introduction: DLT-I Transformer Insulating Oil Dielectric Loss Tester is used to measure the dielectric loss factor and DC resistivity of insulating oil. It ...
... source technology, uses four digit and half LCD display value and three digit and half LCD displays the ambient temperature or test current value, it...
...test the turn ratio accuracy, resolution and group ( including Z type) of the instrument transformer turn ratio testers with accuracy at 0.5 or below 0.05. It is composed of two parts: standard three phase P...
Auto Testing High Voltage Test Equipment Dry type Transformer Features: Small and light, with compact structure, no oil leakage, maintenance unnecessary The connecting wire is simple and intuitive, easy to use ...
... Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the CT and PT Rated current: 5A, 1A Rated voltage: ......
Auto High Voltage Dry type Testing Transformer Hipot Test Equipment Product Describtion : Product Features: Small and light, with compact structure, no oil leakage, maintenance unnecessary The connecting wire i...
... Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the CT and PT Rated current: 5A, 1A Rated voltage: ......
...test equipment Product introduction ZXSBF series induction withstand voltage test equipment is designed according to the Chinese standard GB311-61 and the former Ministry of Water and Power issued in January...
...test report Proved 12kV MV CT Current Transformer for Air Insulation Switchgear We are manufacturer for instrument transformer CE Proved 12kV MV Current Transformer for Air Insulation Switchgear 12kV indoor ...
...Transformer Low Frequency Transformer Hospital Single Phase Feature Medical IT system insulation monitoring and fault locating products (seven-piece set) include medical isolation transformers,medical intell...
...Transformer 150kv Three Phase 380v To 220v Step Down Transformer Main data Product Name Three Phase Transformer Product Model SG-150KVA Winding Material Enameled copper wire / enameled aluminum wire Capacit...
...transformer substation 13200V to 480V pad-mounted transformers are made in power ratings up to 10000 kVA,High voltage up to 34.5 kV.and tested in accordance with standards including CSA, IEEE c.57, and DOE a...
... discharge. This series of products feature reasonable structure, high-quality materials, scientific design, rigorous craftsmanship, advanced testing methods 3D drawings Dry transformer features 1)Explosion-...
...Test Frequency Response Analysis Method for Transformer Winding Deformation Tester Transformer winding deformation tester based can make accurate diagnosis on the transformer internal fault based on the meas...
...transformer windings inside, using the frequency response analysis (FRA) method developed and improved by the developed countries. It applies to the detection of internal structure fault in 63kV-500kV power ...