| Sign In | Join Free | My burrillandco.com |
|
...Test Chamber B-T-120(A~E) with ISO Program Setting Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum temperatu...
...Test Chamber (A~E) with ISO Program Setting Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum temperature requ...
...Test Chamber ISO B-T-120(A~E) Program Setting 1℃-15℃/min Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum tem...
...Test Chamber with ISO Program Setting Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum temperature requiremen...
...Test Chamber, 1℃-15℃/min, -70℃~180℃(100℃) Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum temperature requir...
...Test Chamber | GB/T2423/5170/10586 | -70℃~180℃(100℃) Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum tempera...
...Test Chamber | -70℃~180℃(100℃) | GB/T2423/5170/10586 Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum tempera...
...Test Chamber | -70℃~180℃(100℃) | GB/T2423/5170/10586 Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum tempera...
...Test Chamber | -70℃~180℃(100℃) | GB/T2423/5170/10586 Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum tempera...
...Test Chamber, -70℃~180℃(100℃), 1℃-15℃/min, 1KW~2KW Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum temperatu...
...Test Chamber | -70℃~180℃(100℃) | GB/T2423/5170/10586 Rapid temperature change test chamber refrigeration system and compressor: In order to ensure the cooling rate of the test chamber and the minimum tempera...
...:3.4 2. Technical data Catalogue Hitachi DH serie Compressor Type Model Refrigerant Colling Capacity Test Condition Motor Input Current COP Oil Charge BTU/H WATTS WATTS RLA W/W L STANDRAD TYPE E405DHD-38D2YG...
...Testing Apparatus adopts imported double compressor cascade refrigeration, environmentally friendly refrigerant, fast refrigeration speed; Double-layer stainless steel cold bath, built-in medium, no need to ...
...Compressor 503DH-80B2 , 3 phase refrigerator compressor replacement 1.Product Name Hitachi compressor Model:E503DH-80B2 Voltage: 380~415V/3phase/60HZ Refrigerant:R22 BTU:52510 Capacity:14900W COP:6.8 2. Tech...
COMPRESSOR SM120S4VC FOR REFRIGERATOR AC 10HP R22 COLD ROOM FREEZE AIR CONDITIONING Product Description: Performer compressors are scroll compressors used for both 50Hz and 60Hz, can be used for R22,R407c 1. SM...
...Refrigerant Daikin Scroll Compressor JT90GABV1L for cold room cold storageSpecifications 1. Model:JT90GABV1L 2. 3HP,220V/50HZ/1PH 3. Working R22 refrigerant 4. 28710 BTU 5. COP:3.3 6. Technical Sheet Daikin ...
...Refrigeration Daikin Scroll Compressor for cold room air conditionary Specifications 1. Model:JT90BHBY1L 2. 3HP,220V/50HZ/1PH 3. Working R22 refrigerant 4. 29200 BTU 5. COP:3.29 6. Technical Sheet Daikin Scr...
... model could supply: Type Model Refrigerant Cooling Capacity Test Electricity Power Current COP Oil filled BTU/H WATTS WATTS RLA W/W L Standard 303DH-47D2 R22 29500 ......
.... It can also be used for compressors of household refrigerator and air-conditioner to ensure the airtightness of the product and avoid the leakage of harmful substances (refrigerant). The system is able to ...
...compressors is a typical task in the field of refrigeration. Safety aspects also play an important role. With this knowledge and these skills can be acquired. All components are operated and tested with main...