| Sign In | Join Free | My burrillandco.com |
|
IEC Porcelain Standoff Insulators/ light gray/ OEM design available Description: ANSI CLASS Rated voltage (kV) Height (mm) cantilever strength (kN) Tensile strength (kN) Torsion strength (N.m) Compression stren...
ABB AF52-40-00-13 1SBL367201R1300 Industrial Servo Motor New More information: The AF52-40-00-13 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3...
ABB Af265-30-11-13 3-Phase Contactor (600 VAC) 350 A plc logic controller The AF265-30-00-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 132 kW / 400 V AC (AC...
...AW13 Polycarbonate IP67 Waterproof Hinged Window 13 Poles with Knurled Screws and Transparent Cover 250*101*28mm Features: • Model No.: AW13. • Poles: 13 Poles / Ways / Modules. • Design based on EN 60309, I...
AF190-30-11-13 1SFL487002R1311 Low Voltage Contactor Block Contactor The AF190-30-11-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling moto...
AF265-30-11-13 1SFL547002R1311 Block Contactor 3 Pole 100-250V The AF265-30-11-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up ...
AF52-30-00-13 1SBL367001R1300 100-250V 50/60Hz DC Contactor New The AF52-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) or 40 hp / 48...
...IEC 62196-2) Fast Portable Charger for Home This EV charger is compact and durable,it can fit most driveways and garage and perfect for home use. When you go to the office, picnic, date and more, you can go ...
... Range AWG 20-8 20-8 20-8 IEC Technical Data Overvoltage Category Ⅲ Ⅲ Ⅱ Contamination Class 3 2 2 Rated Voltage / Current V/A 800 / 40 1000 / 40 1000 / 40 ......
... Range AWG 20-8 20-8 20-8 IEC Technical Data Overvoltage Category Ⅲ Ⅲ Ⅱ Contamination Class 3 2 2 Rated Voltage / Current V/A 800 / 40 1000 / 40 1000 / 40 ......
... Range AWG 20-8 20-8 20-8 IEC Technical Data Overvoltage Category Ⅲ Ⅲ Ⅱ Contamination Class 3 2 2 Rated Voltage / Current V/A 800 / 40 1000 / 40 1000 / 40 ......
... Terminal Block Pitch 13.00mm 600V 40A 11x2P Power Terminal Block Parameter and Drawing Specifications: UL Technical Data B C D Rated Voltage / Current V/A 600 / 40 600 / 40 600 / 5 Wire Range AWG 20-8 20-8 ...
... Range AWG 20-8 20-8 20-8 IEC Technical Data Overvoltage Category Ⅲ Ⅲ Ⅱ Contamination Class 3 2 2 Rated Voltage / Current V/A 800 / 40 1000 / 40 1000 / 40 ......
Barrier Terminal Block Pitch 13.00mm 600V 40A 10P Power Terminal Block Parameter and Drawing Specifications: UL Technical Data B C D Rated Voltage / Current V/A 600 / 40 600 / 40 600 / 5 Wire Range AWG 20-8 20-...
...-20 12-20 12-20 IEC Technical Data Overvoltage Category Ⅲ Ⅲ Ⅱ Contamination Class 3 2 2 Rated Voltage / Current V/A 630 / 32 800 / 32 1000 / 32 ......
... Block Pitch 13.00mm 600V 40A 2-12P Power Terminal Block PBT 20-8 aWG Parameter and Drawing Specifications: UL Technical Data B C D Rated Voltage / Current V/A 600 / 40 600 / 40 600 / 5 Wire Range AWG 20-8 ...
Pitch 13.00mm 300V 30A 2-22P Barrier Terminal Block 10-18AWG Power Terminal Block Parameter and Drawing Specifications: UL Technical Data B C D Rated Voltage / Current V/A 300 / 30 300 / 10 Wire Range AWG 10-18...
IEC62196 Electric Vehicle Clamping Screw Terminal Tester For Plug And Connector Complied Standards & Clauses IEC 62196-1Ed.4CDV 2020 clause 13.3.1 fig12, table 3. Equipment Overview This compliance is used for ...
....5 KV, conforming to or exceeding standards such as DOE 2016, IEEE/ANSI, CSA , IEC , NEMA. The products hold UL/cUL certification (Certificate Numbers: UL-US-2431836-0, UL-CA-2423202-0) and can obtain UL (.....
...13.8KV To 480V With UL Certified Why choose us WINLEY produces a full range of three phase pad mounted transformers with a capacity of 45kva-5500KVA and a voltage of up to 34.5KV. The products meet or even e...