... of load switches and isolated switches and other AC high voltage switches, contact resistance, Arcing contacts and vibration characteristics etc. The functions of Circuit Breaker Analyzer cover all testing ...
... protection screen, which can truly simulate the trip time of circuit breaker device. The tripping and closing of the high voltage circuit breaker were simulated during the entire test to avoid the adverse e...
IEC62133 Test Standard Temperature Range 0℃~100℃ Battery Forced Internal Short Circuit Test Equipment 1. Product Name: Battery forced internal short circuit tester 2. Product Model: GX-6055-CSM Technical Parame...
...Circuit Testing Machine This machine is designed according to the latest requirements of Japanese Industrial Standards JISC 8714: 2007 and IEC62133-2-2017. Simulate the battery to perform forced internal sho...
IEC62133 Test Standard Temperature Range 0℃~100℃ Battery Forced Internal Short Circuit Test Equipment 1. Product Name: Battery forced internal short circuit tester 2. Product Model: GX-6055-CSM Technical Parame...
...Circuit Testing Machine This machine is designed according to the latest requirements of Japanese Industrial Standards JISC 8714: 2007 and IEC62133-2-2017. Simulate the battery to perform forced internal sho...
...Circuit Test Machine Model number: GX-6055-CSM Equipment description This product is designed according to the latest requirements of the latest IEC62133 standard UN38.3 and the Japanese industrial standard ...
...Breakers . It takes the ARM7 unit for core to sample, process and then output; the main characteristic is that it’s operated in alt. This dynaic characterisitics of circuit breaker test instrument has many a...
...Test Instrument I.Introduction The High-Voltage Circuit Breakers Test Instrument is designed to meet the need of testing High-Voltage Circuit Breakers . It takes the ARM7 unit for core to sample, process and...
Dynamic Characteristics Test Kit I.Introduction CBA-II Circuit Breaker Test Kit is designed to meet the need of onsite test the dynamic characteristics of High-Voltage Circuit Breakers . It takes the ARM7 unit ...
Circuit Breaker Test Instrument I.Introduction CBA-II circuit breaker test instrument is designed to meet the need of testing high_voltage switches . It takes the micro controller unit(MCU) for core to sample, ...
...IGBT Type Trench Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 80A Current - Collector Pulsed (Icm) 200A Vce(on) (Max) @ Vge, Ic 2.4V @ 15V, 40A Power - Max 535W Switching ...
... 200W Switching Energy 1.5mJ (on), 2.4mJ (off) Input Type Standard Gate Charge 190nC Td (on/off) @ 25°C 55ns/240ns Test Condition 480V, 39A, 5 Ohm, 15V Reverse Recovery Time (trr) 50ns Operating Temperature ...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 30A Current - Collector Pulsed (Icm) 60A Vce(on) (Max) @ Vge, Ic 2.6V @ 15V, 15A Power - Max 259W ...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 50A Current - Collector Pulsed (Icm) 100A Vce(on) (Max) @ Vge, Ic 2.6V @ 15V, 25A Power - Max 375W...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 80A Current - Collector Pulsed (Icm) 225A Vce(on) (Max) @ Vge, Ic 2.3V @ 15V, 75A Power - Max 428W ...
... - Max 428W Switching Energy 4.5mJ Input Type Standard Gate Charge 470nC Td (on/off) @ 25°C 33ns/330ns Test Condition 400V, 75A, 5 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -40°C ~ 175°C...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 650V Current - Collector (Ic) (Max) 120A Current - Collector Pulsed (Icm) 240A Vce(on) (Max) @ Vge, Ic 2V @ 15V, 80A Power - Max 469W S...
... 454W Switching Energy 2.47mJ (on), 2.16mJ (off) Input Type Standard Gate Charge 150nC Td (on/off) @ 25°C 50ns/200ns Test Condition 400V, 75A, 10 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature ...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 1200V Current - Collector (Ic) (Max) 80A Current - Collector Pulsed (Icm) 160A Vce(on) (Max) @ Vge, Ic 2.6V @ 15V, 40A Power - Max 468W...