| Sign In | Join Free | My burrillandco.com |
|
... system to transform AC voltage and current according to the law of electromagnetic induction and transmit AC power.Distribution transformers usually refer to power transformers operating in the distribution...
...Transformer Feature: Power Range: up to 5W Height: 9.27mm Max Footprint: 13.34mm x 10.7mm Max Toplogy: Forward and Flyback Electrical Specifications @ 25°C - Operating Temperature -40°C to +130°C PA1130NL Pr...
...-typ Double Wound Small Signal Transformer Electrical Specifications @ 25°C - Operating Temperature -40°C to +130°C Product name Pri. Inductance (3-4) 253.4 μH ±10% PA1253NL Lk. Inductance (3-4) with (8, 7, ...
... SECONDS BETWEEN LINES) • INSULATION RESISTANCE: 500VDC MORE THAN 100MΩ. (BETWEEN LINES) • OPERATING TEMPERATURE RANGE: -25°C TO T. (T=120– TEMPERATURE RISE) • INDUCTANCE MEASURED AT 1kHZ, 1V. PART NUMBER IN...
... LOWER PROFILE AND WEIGHT VOLTAGE CHANGE COIL STRUCTURE: TOROIDAL MATERIAL: Copper Winding High permeability EP TYPE TRANSFORMERS ARE WIDELY USED IN SWITCH POWER SUPPLIES,UPS,ELECTRICAL EQUIPMENTS AND LED LA...
...Transformer ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C. RESISTANCE 3-5 @20°C 0.043 ohms max D.C. RESISTANCE 2-1 @20°C 0.130ohms max D.C. RESISTANCE 6-9 tie(6+...
... 60 mΩ max. DC Resistance 3 @ 20°C RDC3 60 mΩ max. DC Resistance 4 @ 20°C RDC4 145 mΩ max. Leakage inductance 100 kHz/ 100 mV LS 0.3 μH...
... base 1.02 A typ. DC Resistance Base 100 kHz/ 100 mV RDC base 344 mΩ max. Leakage Inductance Base Ls base 0.3 μH typ....
...Transformer In Ferrite Core PCB Mounted ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C. RESISTANCE 1-2 @20°C 0.270 ohms max D.C. RESISTANCE 3-5 @20°C 0.115ohms ma...
... 20 mΩ max. DC Resistance 3 @ 20°C RDC3 23 mΩ max. DC Resistance 4 @ 20°C RDC4 100 mΩ max. Leakage inductance 100 kHz/ 100 mV LS 0.5 μH...
... base @ 20°C RDC base 344 mΩ max. Voltage-μSecond base ∫Udt base 32.9 μVs max. Leakage Inductance base 100 kHz/ 100 mV Ls base 0.21 μH typ....
... 14 mΩ max. DC Resistance 3 @ 20°C RDC3 16 mΩ max. DC Resistance 4 @ 20°C RDC4 350 mΩ max. Leakage inductance 100 kHz/ 100 mV LS 0.5 μH...
... 2 @ 20°C RDC2 8 mΩ max. DC Resistance 3 @ 20°C RDC3 8 mΩ max. DC Resistance 4 @ 20°C RDC4 97 mΩ max. Leakage inductance 100 kHz/ 100 mV LS 0.5 μH max....
...°C RDC1 116 Ω max. DC Resistance 2 @ 20°C RDC2 230 Ω max. DC Resistance 3 @ 20°C RDC3 4.0 mΩ max. Leakage inductance 100 kHz/ 100 mV LS 1.4 μH max. Insulation test voltage N1,2 => N3,4,5...
EE Type Small Current Step Down Gate Drive Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 1080 μH min. Leakage inductance 100 kHz/ 100 mV LS 5.0 μH m...
Gate Drive Transformer For Triggering Power Thyristors D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 650 μH min. Leakage inductance 100 kHz/ 100 mV LS 2.9 μH ma...
Power Lighting Gate Drive Transformer For power driver D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 750 μH min. Leakage inductance 100 kHz/ 100 mV LS 4.0 μH ma...
EP Series Saface Mount Type Gate Drive Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 370 μH min. Leakage inductance 100 kHz/ 100 mV LS 1.8 μH max. D...
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance base 10 kHz/ 100 mV Lbase 10.9 μH ±20% Turns ratio N1:N2:N3:N4:N5:N6 n 1:1:1:1:1:1 Rated Current base ΔT = 40K IR ba...
...Transformer Electrical Properties: Properties Test conditions Value Unit Tol. Inductance Base 100 kHz/ 100 mV LBASE 14.7 μH ±20% Turns Ratio n 1:1:1:1:1:1 Voltage-μSecond Base ∫Udt Base 49.3 μVs max. Rated C...