... voltage up to 550V and rated current up to 125A at 50Hz AC, and can withstand rated current and expected short-circuit inrush current up to 80kA dynamic thermal stability. This series of fuse conforms to th...
...current mode, fixed frequency step-up DC/DC converter with an internal 3A, 42V switch. Efficiencies of up to 89% can be achieved in typical applications. It features a programmable soft-start function to lim...
... maximum Output Voltage Drop 1 volt maximum Inrush Current 4.78 Amperes for 10 ms Output Current per common 2 Amperes for 10 ms Output current per channel 0.5 Amperes No. of channels per group Eight (8) chan...
... Technical Specifications for IC693MDL940 Off Response Time 15 ms maximum Inrush Current 5 Amperes Output Current per common 4 Amperes Output current per channel 2 Amperes No. of channels per group Four (4) ...
... maximum Output Voltage Drop 1 volt maximum Inrush Current 4.78 Amperes for 10 ms Output Current per common 2 Amperes for 10 ms Output current per channel 0.5 Amperes No. of channels per group Eight (8) chan...
...current max: 3A Inrush current: 50A Max/240V Efficiency: 87% No load Input power <0.5W Leakage current: <0.25mA/240V DC output Max charging voltage: 54.6V Output voltage tolerance: 5% Max charging current: 0~3A Ripple and noise: 250mVp-p Charging mode: 3- stage, CC,CV,trickle charging Cut off current when charged...
...current max: 3A Inrush current: 50A Max/240V Efficiency: 87% No load Input power <0.5W Leakage current: <0.25mA/240V DC output Max charging voltage: 58.4V Output voltage tolerance: 5% Max charging current: 0~3.5A Ripple and noise: 250mVp-p Charging mode: 3- stage, CC,CV,trickle charging Cut off current when charged...
... 4, Low leakage current, <50uA 5, 3 year warranty Technical data: Input Input voltage: 90-264VAC Frequency: 47-63 Hz Input current: 0.18A max. Inrush current max: 30A@230VAC Leakage current: <50uA Output Output voltage: 1-12V Output current: 100-2000MA 12W...
...current max: 3A Inrush current: 50A Max/240V Efficiency: 87% No load Input power <0.5W Leakage current: <0.25mA/240V DC output Max charging voltage: 58.4V Output voltage tolerance: 5% Max charging current: 0~3.5A Ripple and noise: 250mVp-p Charging mode: 3- stage, CC,CV,trickle charging Cut off current when charged...
...current max: 3A Inrush current: 50A Max/240V Efficiency: 87% No load Input power <0.5W Leakage current: <0.25mA/240V DC output Max charging voltage: 54.6V Output voltage tolerance: 5% Max charging current: 0~3A Ripple and noise: 250mVp-p Charging mode: 3- stage, CC,CV,trickle charging Cut off current when charged...
...current max: 3A Inrush current: 50A Max/240V Efficiency: 87% No load Input power <0.5W Leakage current: <0.25mA/240V DC output Max charging voltage: 54.6V Output voltage tolerance: 5% Max charging current: 0~3A Ripple and noise: 250mVp-p Charging mode: 3- stage, CC,CV,trickle charging Cut off current when charged...
...current protection Input: •Input Voltage : 90 to 264 VAC •Frequency : 47-50/60-63hz •Input current : 0.18A (Max) 100 /240VAC •Inrush current : 15A Max. 120VAC at max. Load 30A Max.240VAC at max. Load •Leakag...
...current from 0.01A to 2.1A Input: •Input Voltage: 100 to 240 VAC •Frequency : 47-50/60-63hz •Input current : 0.5A (Max) 100 /240VAC •Inrush current : 60A Max. at max. Load •Leakage current :0.25 mA Max Outpu...
... Range 200-240Vac Input Frequency Nominal Frequency 50/60Hz Variation Frequency 47-63Hz Max Input Current 15Arms max At any input voltage and rated, DC output rated load Inrush Current 50Amps Max. Cold start...
... Range 200-240Vac Input Frequency Nominal Frequency 50/60Hz Variation Frequency 47-63Hz Max Input Current 3Arms max At any input voltage and rated, DC output rated load Inrush Current 50Amps Max. Cold start ...
5Kvar 7.7mH Three Phase Reactor Single Phase Harmonic Filter Features Capacitor in the reactive power compensation circuit are often subject to harmonic current, inrush current and overvoltage impact, resulting...
...protect power transformer from inrush current impact, as well as has an extremely important role in safety commissioning. Due to the inherent hysteresis of the ferromagnetic materials, after the transformer ...
... current 40A Peak Current 60A Peak current duration 3S Max charge current 40A Capacity range 40 to 60AH Life Cycle 4000 cycles @ 80% DOD Protections and Features Protections Over voltage, Under voltage, Over...