| Sign In | Join Free | My burrillandco.com |
|
...Current 115Vac/≤0.09A, 230Vac/≤0.05A Leakage Current <0.5mA/230Vac Inrush Current Cold start 10A at 230Vac Setup Time 115Vac<2500ms, 230Vac<1000ms (at full load) Output Voltage DC16V Output Current 250mA Max Max. Reted power 4W Ripple & Noise 0.2Vp-p (at full......
...Current 115Vac/≤0.09A, 230Vac/≤0.05A Leakage Current <0.5mA/230Vac Inrush Current Cold start 10A at 230Vac Setup Time 115Vac<2500ms, 230Vac<1000ms (at full load) Output Voltage DC16V Output Current 250mA Max Max. Reted power 4W Ripple & Noise 0.2Vp-p (at full......
.... at 230VAC/50Hz,full load Leakage Current: 0.25mA Max. at 264VAC input Power Consumption: 30W max. Data Rate: 10/100/1000Mbps LED Indicator: ......
...Inrush current active management by power limitation – Very low stand-by current – 3.0V CMOS compatible input – Optimized electromagnetic emission – Very low electromagnetic susceptibility – In compliance wi...
...current : 0.6A (Max) •Inrush current : 60A Max. 230VAC at max Load •Leakage current: 0.25 mA Max Output: •Over voltage protection •Over current protection at 110-200% of lo and Auto-recovery •Over temperatur...
...) 120 /240VAC •Inrush current : 60A Max.240VAC at max Load •Leakage current: 0.25 mA Max Output: •Over voltage protection •Over current protection at 110-200% of lo and Auto-recovery •Electronic short circui...
...Current : 0.4A (Max) 100/240VAC •Inrush Current : 30A Max 120VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of l...
...50A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of lo and Auto-recovery •Electronic short circuit prot...
...Current : 0.4A (Max) 100/240VAC •Inrush Current : 50A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of l...
... : 60A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of lo and Auto-recovery •Electronic short circuit p...
... : 60A Max 100VAC at max Load 100A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-250% of lo and Auto-recovery •Electronic short circuit ...
... : 50A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of lo and Auto-recovery •Electronic short circuit p...
... Current : 0.3A (Max) 100/240VAC •Inrush Current : 50A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of ...
.../60-63HZ •Input Current : 0.15A (Max) 100/240VAC •Inrush Current : 50A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.1mA Max Output: •Over voltage protection •Over current protection ...
...Current : 0.6A (Max) •Inrush Current : 50A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection •at 110-200% of lo and Auto...
...Current : 0.3A (Max) 100/240VAC •Inrush Current : 50A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of l...
... Current : 0.3A (Max) 100/240VAC •Inrush Current : 50A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of ...
...Current : 0.4A (Max) 100/240VAC •Inrush Current : 60A Max 100VAC at max Load 100A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-250% of ...
...Current : 0.4A (Max) 100/240VAC •Inrush Current : 60A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of l...
...Current : 0.4A (Max) 100/240VAC •Inrush Current : 50A Max 100VAC at max Load 60A Max 240VAC at max Load •Leakage Current: 0.25mA Max Output: •Over voltage protection •Over current protection at 110-200% of l...