...impulse 400A Lightning impulse withstand 125/150KV Type YH5W5-21/56 Rated voltage---------kV 21 MOCV ----------------kV 17 Nominal Current-------kV 10 Residual voltage of steep impulse----at 5kA(kV) 60.5 8/2...
...impulse 400A Lightning impulse withstand 170/200KV Type YH10W5-36/98 Rated voltage---------kV 36 MCOV ----------------kV 29 Nominal Current-------kV 10 Residual voltage of steep impulse----at 5kA(kV) 106 8/2...
...impulse 400A Lightning impulse withstand 145/150KV Type YH10W5-24/66 Rated voltage---------kV 24 MOCV ----------------kV 19.5 Nominal Current-------kV 10 Residual voltage of steep impulse----at 5kA(kV) 71.5 ...
...KV) 2000ms square wave impulse current withstand 4/1OMS high current impulse (kV) Steep current impulse switching current impulse 8/20 ms Lightning current impulse HY10W-3 3 2.55 9.5 7.7 9 100 100 HY10W-6 6 ...
... stability, widely used in impulse current test of MOA valve and SPD, as well as other test research. Technology index accords with national standard and IEC standard, is in the leading position at home and ...
Impulse tester IEC 61010-1-clause 14.8 Circuits used to limit transient vervoltages Product Overview The KP-3950S combined wave pulse generator is a high-precision simulation test device developed for lightning...
...lightning arr Hot Sale zinc oxide varistor Product Description Type Rated voltage (kV) MCOV (kV) Residual voltage (KV) 2000ms square wave impulse current withstand 4/1OMS high current impulse (kV) Steep curr...
... 1. Ultra-large capacity design: peak current 12kA, optimized for short-circuit/lightning current detection in power systems. 2. High-frequency bandwidth 50MHz: supports microsecond transient waveform analys...
... ≤KV 30/60μs Switching Current Impulse (≤KV) 2msRectangular Current Impulse(2ms) (A) 4/10μs High Current Impulse (KA) KV(r.m.s) HY1.5W-0.28/1.3 0.22 0.28 0.24 0.6 1.3 75 25 HY1.5W-0.5/2.6 0.38 0.5 0.42 1.2 2...
...Lightning Arrester With KEMA Type Test Report Porcelain Surge Arrester: This zinc oxide arrester is mainly used to protect distribution transformer,cable connector and electrical equipment from being damaged...
...lightning arrester 11kv 5ka lightning arrester Hot Sale 9kv polymer metal oxide surge lightning arrester Product Description Type Rated voltage (kV) MCOV (kV) Residual voltage (KV) 2000ms square wave impulse...
...) 2000ms square wave impulse current withstand 4/1OMS high current impulse (kV) Steep current impulse switching current impulse 8/20 ms Lightning current impulse HY10W-3 3 2.55 9.5 7.7 9 100 100 HY10W-6 6 5....
...lightning arrester Factory direct stainless steel lightning rod Product Description Type Rated voltage (kV) MCOV (kV) Residual voltage (KV) 2000ms square wave impulse current withstand 4/1OMS high current im...
...lightning arrester High quality safety more types of lightning arrester Product Description Type Rated voltage(KV) MCOV (KV) Residual voltage(KV) 2000ms square wave impulse current withstand 4/10MS high curr...
...Impulse Voltage Generator 20KV High-Voltage Impulse Product Information: The Impulse Test Generator conforms to the standard requirements of IEC 60664-1 clause 6.2.2.1, etc. It is used to verify that the app...