Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 10-8000 - 1:1 - - Frequency Range 10-8000 - - - MHz Insertion Loss 10-8000 - 1.0 2.0 dB Amplitude Unbalance 10-8000 - - 0....
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 3-300 - 1:2 - - Frequency Range 3-300 - - - MHz Insertion Loss 3-300 - 1.0 2.0 dB Amplitude Unbalance 3-300 - - 0.5 dB Pha...
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 30-3000 - 1:2 - - Frequency Range 30-3000 - - - MHz Insertion Loss 30-3000 - 1.0 2.0 dB Amplitude Unbalance 30-3000 - - 0....
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 30-6000 - 1:2 - - Frequency Range 30-6000 - - - MHz Insertion Loss 30-6000 - 1.0 2.0 dB Amplitude Unbalance 30-6000 - - 0....
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 3-800 - 1:4 - - Frequency Range 3-800 - - - MHz Insertion Loss 3-800 - 1.0 2.0 dB Amplitude Unbalance 3-800 - - 0.5 dB Pha...
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 200-1400 - 1:4 - - Frequency Range 200-1400 - - - MHz Insertion Loss 200-1400 - 1.0 2.0 dB Amplitude Unbalance 200-1400 - ...
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 20-4500 - 1:4 - - Frequency Range 20-4500 - - - MHz Insertion Loss 20-4500 - 1.0 2.0 dB Amplitude Unbalance 20-4500 - - 0....
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 0.08-200 - 1:1 - - Frequency Range 0.08-200 - - - MHz Insertion Loss 0.08-200 - 1.0 2.0 dB Amplitude Unbalance 0.08-200 - ...
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 50-1000 - 1:4 - - Frequency Range 50-1000 - - - MHz Insertion Loss 50-1000 - 1.0 2.0 dB Amplitude Unbalance 50-1000 - - 0....
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 0.3-140 - 1:8 - - Frequency Range 0.3-140 - - - MHz Insertion Loss 0.3-140 - 1.0 2.0 dB Amplitude Unbalance 0.3-140 - - 0....
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 0.015-300 - 1:1 - - Frequency Range 0.015-300 - - - MHz Insertion Loss 0.015-300 - 1.0 2.0 dB Amplitude Unbalance 0.015-30...
Electrical Specifications Parameter Frequency (MHz) Min. Typ. Max. Unit Impedance Ratio 0.3-200 - 1:2 - - Frequency Range 0.3-200 - - - MHz Insertion Loss 0.3-200 - 1.0 2.0 dB Amplitude Unbalance 0.3-200 - - 0....
...effectively remove water, gas, oxide materials, fee carbon and other impurities from transformer oil to lower the PH value, improve breakdown voltage and quality. This vacuum insulation oil filtration machin...
DIN standard 42539 , AB-3150-42539 LV transformer bushing insulator brown color Specifications: TYPE d5 d7 d8 d9 max d10 min d 13 r1 CODE NO A3-3150 145 100 100 86 50 125 1.5 A1-3150-42539N TYPE d4 d6 e2 d11 mi...
...Length Line High-Precision Transformer Core Lamination Production Machine The JY-300 Double Shear Double Punch Cut-to-Length Line is a fully automatic production solution designed for high-precision processi...
... Line High-Speed Transformer Core Lamination Production Machine The JY-400 Double Shear Double Punch Cut-to-Length Line is a high-efficiency, fully automatic production system designed for processing silicon...
...Line High-Precision Transformer Core Lamination Production Machine 6 The JY-500 Silicon Steel Cut-to-Length Line is a fully automatic high-speed production system specially designed for processing grain-orie...
...(1Aoutput),5VA(5A output), 4Ω (mA output) Installation Suspension Output Lead output Outdoor Split-core Current Transformer Application - Utility pole probe monitoring &...
...Transformer KH80 Technical Parameters Load capacity <=4ohm (mA output); <=1VA (1A output); <=5VA (5A output, 600-1000A); <=2.5VA (5A output, <=500A) Diameter 80mm Dimension 193*138*28mm Weatherproof Outdoor Split-core Current Transformer IP68 0.5 or 0.2 Class Power Distribution line monitoring outdoor split-core current transformer......
... (secondary 1A ), 5VA(Secondary 5A) Installation Bracket Output terminal output Features Outdoor Split-core Current Transformer Application - Utility pole probe monitoring &...