| Sign In | Join Free | My burrillandco.com |
|
...O2 CLE-0231-S00 Classic Line Mini O2 Sensor Oxygen Gas Sensor 0~30% Live More Than 2 Years Performance characterization: Response time: (T90) ≤ 15 seconds linearity Long-term stability: < 2% signal value /3 ...
... and high output current. · Easy handling of complex gases. · Excellent linearity. · Long life and strong stability. · Durable in complex environments. Output value in clean atmosphere (baseline) < ± 10 ppm ...
TGS5042 - for the detection of Carbon Monoxide Features: * Battery operable * High repeatability/selectivity to carbon monoxide (CO) * Linear relationship between CO gas concentration and sensor output * Low se...
TGS5141 - for the detection of Carbon Monoxide Features: * Ultra compact * Battery operable * High repeatability/selectivity to CO * Linear relationship between CO gas concentration and sensor output * Simple c...
...detection of Carbon Monoxide Features: * Battery operable * Compact size * High repeatability/selectivity to CO * Linear relationship between CO gas concentration and sensor output * Simple calibration * Lon...
... and highly reliable. This product is designed with embedded technology and has the function of detecting linear attenuation compensation. It comes with an output interface for an audible and visual alarm an...
...Gas Sensor Product Review: The AO-08 oxygen sensor is an electrochemical sensor specifically designed for measuring oxygen concentration in medical equipment. It adopts a molded body design and features rapi...
...Gas Sensor Product Overview: The AO-09 oxygen sensor is an electrochemical sensor specifically designed for measuring oxygen concentration in medical equipment. It adopts a molded body design and features ra...
MOX-20 Gas oxygen sensor Basic Parameters: Measurement Range: 0%–100% O₂ Output Signal: 13–16 mV in air Circuit Interface: 3-pin (Molex) Accuracy & Repeatability: <1% O₂ by volume (after calibration in 100% O₂) Linearity Error: <3% relative error......
...ppm features excellent linearity, strong stability, and is based on electrochemical technology principles, ensuring safety and reliability Performance characterization Product model CLE-3611-......
AOM-09 Oxygen Gas Sensors Partial Pressure Electrochemical About 40g Oxygen sensor * Full range linear output * No external power supply required for operation * Temperature compensation * Fast response * Accur...
ANH3000 Ammonia Gas Sensor Low Power Consumption Signal Output Ammonia sensor âš« Stable signal output âš« Fast response âš« Low power consumption âš« High linearity Product Description ANH3000 is a three-electrode ele...
.... Wide linear range and strong anti - interference ability. Excellent repeatability and stability. Used: Ammonia Alarm Systems: It can be used as a key component in ammonia ......
...: YJJ MST 7C2H5OH-10 7 Series Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices Features: Reproducibility: 1% output signal Operating temperature range: Linear, regression coefficient R = 0...
...: YJJ 7C2H5OH-100 7 Series MST Electrochemical Ethanol Sensor Is Used In Gas leakage Alarm Devices Features: Reproducibility: 1% output signal Operating temperature range: Linear, regression coefficient R = ...
.../ppm, it can accurately measure the chlorine concentration within the range of 0 - 20 ppm (linear range), and the resolution can reach 0.02 ppm. Fast Response: The response time of the sensor is less than 60...
CO-AX Carbon Monoxide Gas Sensor Low Cross Sensitivity To Hydrogen Specification: Sensitivity 55–100 nA/ppm (400 ppm CO) T90 Response <30 s (0 → 400 ppm) Baseline <±3 ppm equivalent Resolution <0.5 ppm (RMS noise) Linearity <±40 ppm (0–2000 ppm; 0–800 ppm ......
... Carbon Monoxide Sensor Resistant To H2 For Gas Detection Features: Carbon Monoxide Sensor - AX Main Characteristics Measurement Range: 2000 ppm Sensitivity: 55 - 90 nA/ppm Response Time: < 30 seconds Linear...
...Gas SF6 Sensor NDIR Sensor Features: Feature: Infrared light source based on microelectronic technology Standard sensor size: 7 series 32mm Includes all necessary optical components, circuits and hardware, p...
... sensor's three - electrode structure and liquid electrolyte interact with ammonia, generating a current signal that is linearly proportional to the ammonia concentration, with a sensitivity of 15nA/ppm±...