...Kit The below diaphragm is used to repair 1.5'' BFEC DMF-Z-40S, DMF-ZM-40S, DMF-Y-40S pulse jet valve. The complete 1 set including 1 pc main diaphragm, 1pc secodary diaphragm, 2 pcs springs. Pulse jet valve...
... jet valve is either operated by internal Solenoid Operator or remote pilot solenoid valve. When the pilot solenoid valve is energised, the air trapped above the diaphragm is quickly exhausted through...
..., 1 pc secnodary diaphragm, 2 pcs springs. Pulse jet valves are operated by integral solenoid pilot operator. When the valve is energised, the trapped air above pulse valve diaphgram is quickly exhausted cau...
... is -10 to +120 ℃. Pulse jet valves are indirect operated solenoid valves especially designed for dust collector systems. When the solenoid is energized, trapped air above a...
...Kit For Mecair Pulse Jet Valve VNP206 VNP306 DB16 ( DB16/G ) Diaphragm ( Membrane ) for Mecair pulse valve VNP206, VEM206, VNP306, VEM306; NBR material is standard, working temperature range is -5 to +80 ℃; ...
...Kit For Mecair Pulse Jet Valve DB16 ( DB16/G ) Diaphragm ( Membrane ) for Mecair pulse valve VNP206, VEM206, VNP306, VEM306; NBR material is standard, working temperature range is -5 to +80 ℃; Viton material...
...Pulse Jet valves are also called as dust collector. They are indirect type solenoid valves. When the solenoid of pulse jet valves gets energized, air trapped in the diaphragm is exhausted causing pressure di...
... are indirect operated solenoid valves especially designed for dust collector systems. When the solenoid is energized, trapped air above a diaphragm is quickly exhausted causing a high pressure difference ac...
... Kit For 3'' 8296900.8171 8297900.8171 1271526 Diaphragm (Membrane) for 3'' Norgren Buschjost pulse valve 8296900.8171, 8297900.8171; TPE material; Pulse valves are operated by integral solenoid pilot operat...
... and 1pc spring. Pulse valves are operated by integral solenoid pilot operator. When the valve is energised, the trapped air above pulse valve diaphgram is quickly exhausted causing fast opening of main diap...
... temperature, working temperature range is -10 to +120 ℃. Pulse valves are operated by integral solenoid pilot operator. When the valve is energised, the trapped air above pulse valve diaphgram is...
...Kit For Goyen Pulse Valve K4000 (M1182), K4007 (M1156) Diaphragm for Goyen pulse valve CA40MM, RCA40MM; NBR material is standard, working temperature range is -5 to +80 ℃; VITON material is optional, for hig...
...Kit K4000 K4007 For CA40MM RCA40MM K4000 (M1182), K4007 (M1156) Diaphragm for Goyen pulse valve CA40MM, RCA40MM; NBR material is standard, working temperature range is -5 to +80 ℃; VITON material is optional...
... is -10 to +120 ℃. Pulse jet valves are indirect operated solenoid valves especially designed for dust collector systems. When the solenoid is energized, trapped air above a...
...Kit For Old Version 2'' DMF-Z-50S Diaphragm (Membrane) for Old Version 2'' BFEC pulse valve DMF-Z-50S, DMF-Y-50S, DMF-T-50S; NBR material is standard, working temperature range is -5 to +80 ℃; Viton material...
... is -10 to +120 ℃. Pulse Jet valves are indirect type solenoid valves. When the solenoid of pulse jet valves gets energized, air trapped in the diaphragm is...
... operated solenoid valves especially designed for dust collector systems. When the solenoid is energized, trapped air above a diaphragm is quickly exhausted causing a high pressure difference across the diap...
...indirect type solenoid valves. When the solenoid of pulse jet valves gets energized, air trapped in the diaphragm is exhausted causing pressure difference in the diaphragm. Then the diaphragm is suddenly ope...
... the solenoid of pulse jet valves gets energized, air trapped in the diaphragm is exhausted causing pressure difference in the diaphragm. Then the diaphragm is suddenly opened. When it is de-energized, air p...
...Kit For Taeha TH-4820-B TH-4820-C MD01-20, MD02-20 Diaphragm (Membrane) for Taeha pulse valve TH-5820-B, TH-4820-B, TH-5825-B, TH-5820-C, TH-4820-C; Pulse Jet valves are indirect type solenoid valves. When t...