| Sign In | Join Free | My burrillandco.com |
|
Enerkey Standard NMC/LFP/LTO/SIB BMS 3S 4S 10A-80A Peak 150A With NTC and Balancing Cell Hardware BMS Product Description When is a BMS Necessary? A BMS is crucial in the following scenarios: High-Capacity Batt...
Product Description Enerkey Hardware BMS 6S 200A Lto Battery Protection Board with Balance NTC for EV The core role of lithium battery protection board in electric vehicles: it plays a multiple role as a guardi...
Product Description Enerkey Hardware BMS 7S 200A Peak 300A Li-ion Lithium Battery Pack with Balancing Function Lithium iron phosphate batteries cannot be without protection boards. Lithium iron phosphate batter...
Product Description Enerkey Hardware BMS 200A 5S 6S 7S 12V 24V Battery Protection Board With Passive Balance and NTC Types of lithium battery protection boards: 1. From the overcharge and over-discharge functio...
...load cell Specifications: Rated Load: 50/60/80/100/150/200/300kg Sensitivity: (2.0±0.1%) mV/V Insulation Resistance: ≥5000MΩ Combined Error: ±0.03% F.S Operating Temp. Range: -30~+70℃ Creep Error(30min): ±0....
...load cells AM650 (keli UDB,zemic L6E) used for bench scales Specifications: Rated Load: 5/10/15/20/50/100/120/200/300kg Sensitivity (2.0±0.1%) mV/V Operating Temp. Range -30~+70℃ Combined Error ±0.02% F.S Ma...
...Load Cell used in 500x600mm 500kg bench scale Specifications: Rated Load: 50kg~1000kg Insulation Resistance: ≥5000MΩ Sensitivity: (2.0±0.1%) mV/V Operating Temp.Range: -30~+70℃ Combined Error: ±0.03% F.S Max...
... Combined Error: ±0.02% F.S Ultimate Over Load: 300%F.S Creep Error(30min): ±0.02% F.S Recommend Excitation: 10~12VDC Zero Balance: ±1% F.S Maximum Excitation: 15V DC Temp. Effect On Zero: ±0.02% F.S/10℃ Sea...
...: 150%F.S Combined Error: ±0.02% F.S Ultimate Over Load: 250%F.S Creep Error(30min): ±0.02% F.S Recommend Excitation: 10~12V DC Zero Balance: ±1% F.S Maximum Excitation: 15V DC Tco: ±0.02% F.S/10℃ Sealing Cl...
... Combined Error: ±0.02% F.S Ultimate Over Load: 300%F.S Creep Error(30min) ±0.02% F.S Recommend Excitation: 10~12VDC Zero Balance: ±1% F.S Maximum Excitation: 15V DC Temp. Effect On Zero: ±0.02% F.S/10℃ Seal...
...05% F.S Max. Safe Over Load: 150%F.S Creep Error(30min): ±0.02% F.S Ultimate Over Load: 250%F.S Zero Balance: ±1% F.S Recommend Excitation: 10~12V DC Temp. Effect On Zero: ±0.017% F.S/10℃ Maximum Excitation:...
...load cell 200klb Specifications: Rated Load: 5/10/20/30/60/100/150/200klb Sensitivity: (2.0±0.1%) mV/V Operating Temp. Range: -30~+70℃ Combined Error: ±0.03% F.S Maximum Safe Over Load: 150%F.S Creep Error(3...
...: 150%F.S Combined Error: ±0.05% F.S Ultimate Over Load: 250%F.S Creep Error(30min): ±0.05% F.S Recommend Excitation Vol.: 10~12V DC Zero Balance ±1% F.S Maximum Excitation Vol.: 15V DC Temp. Effect On Zero:...
...load cell used for weighbridge truck scale Specifications: Rated Load: 5/10/20/25/30/40/50t Operating Temp. Range: -30~+70℃ Sensitivity: (2.0±0.1%) mV/V Max. Safe Over Load: 150,120 (40~50t)%F.S Combined Err...
...load weighing device load cell/3t force sensor micro force load sensor Specifications: Rated Load: 1.2/3t Input Resistance: 760±10Ω Rated Output: 2.0±0.02%m V/V Output Resistance: 700±2Ω Total Error: ±0.5%FS...
...r Load: 150%F.S Combined Error: ±0.02% F.S Ultimate Over Load: 300%F.S Creep Error(30min): ±0.02% F.S Recommend Excitation: 10~12V DC Zero Balance: ±1% F.S Maximum Excitation: 15V DC Temp. Effect On Zero: ±0...
...30~+70℃ Combined Error: ±0.03% F.S Maximum Safe Over Load: 150%F.S Creep Error(30min): ±0.03% F.S Ultimate Over Load: 200%F.S Zero Balance: ±1% F.S Recommend Excitation Vol.: 10~12V DC Temp. Effect On Zero: ...
...30~+70℃ Combined Error: ±0.03% F.S Maximum Safe Over Load: 150%F.S Creep Error(30min): ±0.03% F.S Ultimate Over Load: 200%F.S Zero Balance: ±1% F.S Recommend Excitation Vol.: 10~12V DC Temp. Effect On Zero: ...
...Load Cells for Various Electronic Weighing Devices Specifications: Rated Load: 50kg~1000kg Insulation Resistance: ≥5000MΩ Sensitivity: (2.0±0.1%) mV/V Operating Temp.Range: -30~+70℃ Combined Error: ±0.03% F....
... mV/V Operating Temp. Range -30~+70℃ Combined Error ±0.02% F.S Maximum Safe Over Load: 150%F.S Creep Error(30min): ±0.02% F.S Ultimate Over Load: 250%F.S Zero Balance ±1% F.S Recommend Excitation Vol.: 10~12...