| Sign In | Join Free | My burrillandco.com |
|
... Output Resistance: 702±2Ω Wireless Distance: Min:800m Insulation Resistance: ≥5000MΩ A/D Conversion Rate: ≥50 times/seconds Operating Temp. Range -30~+70℃ Battery Life: ≥50 hours Max.Safe Over Load: 120%F.S...
...Load Cell Load Cell Dimension: Load Cell Technical Parameter Items UNIT TECHNICAL DATA Rated capacities(Emax) KG 1, 2, 3, 5, 10, 20, 50, 100(XSGB) Sensitivity mV/V 0.5(1kg), 1.0(2~100kg) Total error F.S ±0.2...
...Load Cell Load Cell Dimension Load cell Parameter: Items UNIT TECHNICAL DATA Rated capacities(Emax) T 1, 2, 3, 5, 10, 20 Sensitivity mV/V 2.0±0.006 Total error F.S ±0.05%(2, 3, 5T); ±0.1%(10, 20T) Creep erro...
...0.015 Creep for 30 min. (% R.O) ≤0.017 Excitation Recommended (V) 9 Maximum (V) 27 Compensated Temerature Range(˚C) -10~+40 Operating Temperature Range(˚C) -40~+70 Material & Plate Stainless Steel We special...
... (% R.O) ≤0.015 Creep for 30 min. (% R.O) ≤0.017 Excitation Recommended (V) 9 Maximum (V) 27 Compensated Temerature Range(˚C) -10~+40 Operating Temperature Range(˚C) -20~+70 Material & Plate Nickel Plated St...
...Load Cells WBKE-30T Analog load cell Stainless Steel Weighbridge load cell specification: Model WBKE Rated Capacity (kgf) 10K,20,25K,30K Accuracy Class C3 Combined Error (% R.O) ≤0.02 Creep for 30 min. (% R....
...Load Cells WBK-30T Analog load cell Stainless Steel Weighbridge load cell specification: Model WBK Rated Capacity (kgf) 10K,20K,25K,30K,50K Accuracy Class D3 C3 Combined Error (% R.O) ≤0.03 ≤0.02 Creep for 3...
...Load Cell Display Unit | DIN Rail Force Meter Digital Indicator The FGT load cell readout is a multifunctional signal conditioning device designed for seamless integration with load cells and force transduce...
...Load Cell | Bespoke Submersible Load Pin The custom underwater pin load cell is purpose-built for demanding subsea and offshore applications where accurate, long-term force measurement is essential. Engineer...
... TC SPAN F.S/℃ ±0.1% / 10 Input impedance Ω 400±20 Output impedance Ω 352±3 Insulation impedance MΩ ≥5000 Temperature range, operating ℃ -30~...
...Load Cell For Platform Scales Notice: We have different types of sensors from 20kg-400t, different kinds of sensors and matching power supply and junction box, etc., there are new explosion-proof products fo...
...installation; * Suitable for agriculture, animal husbandry feed truck, grain cart scale weighing. Specification Rated Load 7.5t Compensated Temp.Range -35~+70℃ Comprehensive Error ±0.5%F.S Operating Temp.Ran...
.../V Output Resistance 1000±10Ω Non-linearity ±1%F.S Insulation Resistance ≥2000MΩ (50V) Repeatability ±1%F.S Excitation Voltage ≤10V Hysteresis ±1%F.S Operation Temp.Range -10--+40℃ Creep ±0.05(5min)%F.S...
...: 200%F.S Zero Balance: ±1% F.S Construction: Alloy Steel, SS TC SPAN: ±0.02%FS/10℃ Protection Class: IP65 Operating Temp....
...load cell sensor 800kg Specifications: Rated Load: 5000kg Input Resistance: 760±10Ω Rated Output: 2.0±0.02%m V/V Output Resistance: 700±2Ω Total Error: ±0.5%FS Insulation Impedance: ≥5000MΩ Repeatability: ±0...
... Output Resistance: 351±2Ω A/D Conversion Rate: ≥50 times/seconds Insulation Resistance: ≥5000MΩ Battery Life: ≥50 hours Operating Temp. Range: -30~+70℃ Sensitivity: (2.0±0.1%...
... Output Resistance: 351±2Ω A/D Conversion Rate: ≥50 times/seconds Insulation Resistance: ≥5000MΩ Battery Life: ≥50 hours Operating Temp. Range: -30~+70℃ Sensitivity: (2.0±0.1%) m V/V Max. Safe Over...
...-H-XP1 Elevator load weighting device .elevator parts load cell Type EWD-H-XP1 Elevator Load cell/ elevator parts INTRODTION MANUAL ● This system is applicable to all elevators with movable car platform and ...
...LOAD CELL: High Temperature Sleeper LOAD CELL DATA Rated Load 30t Sensitivity 2.00±0.001mV/V Total Error ±0.05%F.S Creep(30minutes) ±0.02%F.S Recommended Excitation Voltage 5-18V Maximum Excitation Voltage...