| Sign In | Join Free | My burrillandco.com |
|
.../LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 18 20 24 Rated Gas Output(kw) 15.9 17.6 21.1 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 110 Temp.Ra...
...Gas Type NG/LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 20 24 Rated Gas Output(kw) 17.6 21.1 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 Temp.Ran...
... NG/LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 16 18 20 Rated Gas Output(kw) 14.1 15.9 17.6 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 110 Temp...
... Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 Temp.Range Of Heating Water(℃) Radiator:30-80 Floor Heating:30-60 Heating Area(㎡) 80-160 Lift Of pump(m) 5 ......
...LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 16 18 Min. Heat Input(kw) 6.7 7.6 Min. Heat Output(kw) 5 5.7 Efficiency Under Rated Heat Input(%) About 88% Power Supply AC220V-50HZ Electric Power 11...
... Under Rated Heat Input(%) Above 88% Power Supply 20-50HZ Electric Power(W) 110 110 110 110 Temp.Range Of Heating Water(℃) Radiator:30-80 Floor Heating:30-60 Heating Area(...
.../LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 18 20 24 28 32 36 Rated Gas Output(kw) 15.9 17.6 21.1 24.7 28.2 31.7 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Powe...
....7 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 Temp.Range Of Heating Water(℃) Radiator:30-80 Floor Heating:30-60 Heating Area(㎡) 100-200 160-260 ......
...L1PB28 Gas Type NG/LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 24 28 Rated Gas Output(kw) 21.1 24.7 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 T...
... NG/LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 18 20 24 Rated Gas Output(kw) 15.9 17.6 21.1 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 110 Temp...
.../LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 18 20 24 Rated Gas Output(kw) 15.9 17.6 21.1 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 110 Temp.Ra...
... Gas Type NG/LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 32 Rated Gas Output(kw) 28.2 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 145 Temp.Range Of Heati...
...LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 16 18 20 24 32 36 Rated Gas Output(kw) 14.1 15.9 17.6 21.1 28.2 31.7 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power...
....9 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 Temp.Range Of Heating Water(℃) Radiator:30-80 Floor Heating:30-60 Heating Area(㎡) 60-120 70-140 ......
....2 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 145 Temp.Range Of Heating Water(℃) Radiator:30-80 Floor Heating:30-60 Heating Area(㎡) 100-200 200-300 ......
.../LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 20 24 32 Rated Gas Output(kw) 17.6 21.1 28.2 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 145 Temp.Ra...
.../LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 16 18 20 Rated Gas Output(kw) 14.1 15.9 17.6 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 110 Temp.Ra...
...NG/LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 16 18 20 Rated Gas Output(kw) 14.1 15.9 17.6 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 110 Temp....
.../LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 16 18 20 Rated Gas Output(kw) 14.1 15.9 17.6 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 110 110 110 Temp.Ra...
... Gas Type NG/LPG Rated Gas Pressure(Pa) 2000/2800 Rated Gas Input(kw) 40 Rated Gas Output(kw) 35.2 Efficiency Under Rated Heat Input(%) Above88% Power Supply 20-50HZ Electric Power(W) 200 Temp.Range Of Heati...