| Sign In | Join Free | My burrillandco.com |
|
... and voltage are closed links, which you need to isolate them. As for the multi-position power meter auto-calibration system, it should add the three phase isolated current transformer: HS-9503. At present, ...
Portable Transformer Testing Machine TTR Tester 8kg Weight 12 Points Group Product Description By measuring the ratio of the transformer ratio bridge, the operation process is complicated, the measuring range i...
...Transformer Turns Ratio Group Tester RSBC-V Product Introduction 1. The instrument is equipped with lithium battery, which can be used for ratio variation test on site without external power supply. A single...
...IV Transformer Testing Equipment Load and No Load Power Analyzer (Table type) Product Description RSBTC-IV Power Analyzer is a high-accuracy instrument meticulously researched and developed by our company, e...
RSHL-200A CT PT Testing Equipment High Accuracy 0.05 class 200A Standard Current Transformer Product Description The function of the Current Transformer and Votage Transformer is to reduce the AC voltage and th...
...Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer Product Description Purpose The function of the transformer is to reduce the ac voltage and the large current in proportion to the...
... damp deterioration of electrical equipment insulation, as well as local defects. In electrical manufacturing, electrical equipment installation, transfer and preventive tests are widely used. Measuring diel...
... with IEC60044-1 / GB1208, IEC60044-2GB1207, IEC60044-6 / GB16847 and C57.13, the instrument can obtain excitation characteristic of current and voltage transformer, excitation parameters, turns ratio, turns...
...Transformer Insulating Oil Dielectric Loss Tester Introduction: DLT-I Transformer Insulating Oil Dielectric Loss Tester is used to measure the dielectric loss factor and DC resistivity of insulating oil. It ...
... source technology, uses four digit and half LCD display value and three digit and half LCD displays the ambient temperature or test current value, it...
..., PVC and coating test block, put coating of test block upward and under ram of the machine and check damage and transformation condition after heavy punch falling and strike of a certain height. Test standa...
... a toroidal, double winding and multi-winding, EE transformer, ERL35 high frequency transformer and ERL transformer structure, our transformer is made with high-quality copper and copper wire plus ferrite co...
...test report Proved 12kV MV CT Current Transformer for Air Insulation Switchgear We are manufacturer for instrument transformer CE Proved 12kV MV Current Transformer for Air Insulation Switchgear 12kV indoor ...
...Test Frequency Response Analysis Method for Transformer Winding Deformation Tester Transformer winding deformation tester based can make accurate diagnosis on the transformer internal fault based on the meas...
...transformer windings inside, using the frequency response analysis (FRA) method developed and improved by the developed countries. It applies to the detection of internal structure fault in 63kV-500kV power ...
...protect power transformer from inrush current impact, as well as has an extremely important role in safety commissioning. Due to the inherent hysteresis of the ferromagnetic materials, after the transformer ...
10/100Base Ethernet Lan Transformer HX1260FNL For Loop Powered Devices Description: 1.Gigabit Lan Transformer L24N001-0 2.Designed to support dual gigabit ethernet 3.100% Tested (Not Just Batch Tested) 4.Meets ...
... : W2 n 1 : 125 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 68 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V (AC) E...
... : W2 n 1 : 60 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 30 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V (AC) E General information: It is...
... : W2 n 1 : 40 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 20 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V (AC) E General information: It is...