Ultrasonix EC9-5/10 Endo-cavitary probe for repair Brief Description Fault: Bad array element. Solution: Replace crystal and housing. Problem & Solutoin Brand Ultrasonix Model EC9-5/10 Fault Bad array elemen...
Hitachi C41V1 Ultrasuound probe for repair Brief Description Fault: Lens problem. Solution: Replace lens. Problem & Solutoin Brand Hitachi Model C41V1 Fault Lens problem Solution Replace lens Common issues...
GE RIC6-12-D endocavity probe for repair Brief Description Fault: Lens problem. Solution: Replace lens,Clean cable. Problem & Solutoin Brand GE Model RIC6-12-D Fault Lens problem Solution Replace lens,Clean ...
Karl Storz 27005BA endoscope for repair Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Repl...
Olympus CF-240L Colonoscope for repair Brief Description Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch. Solution: Replace rubber, objective lens...
OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR Brief Description Fault: 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leaka...
C5-1 convex probe for repair Brief Description Fault:Lens problem, cable broken, without strain relief. Solution:Replace probe lens, replace a new cable, replace strain relief. Problem & Solutoin Model C5-1 ...
L15-7io Linear probe for repair Brief Description Fault: Lens problem. Solution: Replace probe lens. Problem & Solutoin Model L15-7io Fault Lens problem Solution Replace probe lens Common issues with L15-7...
Samsung Medison P2-4AH Cardiac probe for repair Brief Description Fault:Lens problem, crystal damage. Solution:Replace probe lens, replace crystal. Problem & Solutoin Brand Samsung Model P2-4AH Fault Lens pr...
Olympus CF-H190L Colonoscope for repair Brief Description Fault: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leakin...
STORZ 13820pks Gastroscope for Repair Brief Description Fault: 1.Rubber leakage; 2.Wire abrasion; 3. no up angle, other angle lack of. Solution: 1. Replace the wires, coil pipe, rubber; 2.Adjust angle. Probl...
Olympus GIF-Q150 gastroscope for repair Brief Description Fault: 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and ...
Olympus TJF-160VR endoscope for repair Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube brok...
Olympus GIF-Q180 gastroscope for repair Brief Description Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending secti...
Olympus GIF-H180J gastroscope for repair Brief Description Fault: 1.image with shadow; 2.light bundle broken; 3.insert tube with bite mark; 4.biopsy tube abrasion; 5.bending section serious deformation; 6.wir...
Olympus GIF-H170 gastroscope for repair Brief Description Fault: 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Inse...
Olympus GIF-1TQ160 gastroscope for repair Brief Description Fault: 1.With image, but CCD with broken. 2.Light bundle broken completely. 3.Insert tube abrasion. 4. No biopsy tube. 5. No air&water tube, no wate...
Olympus CHF-P20Q endoscope for repair Brief Description Fault: 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution: Replace image bu...
Olympus CF-Q160AL scope for repair Brief Description Fault: 1.No image, CCD broken; 2.image broken completely; 3.insert tube aging; 4.biopsy tube abrasion; 5.bending section abrasion; 6.wires and helix tube a...
Olympus CF-2T160L Colonoscope for repair Brief Description Fault: 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wi...