| Sign In | Join Free | My burrillandco.com |
|
... Ratio 1:1000/2500/5000/10000 Primary Current 10 A Secondary Current 1/2/4/10 mA Burden (Rb) 5~100 Ω Accuracy Class 0.1/0.2/0.5 Class DC Immunity Error <3% Busbar Type as required Mounting Method as required Accept Customized Yes Product Description 1...
...current transformer pin type CT with 4 pins for measurement PCB Mounting Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-882 Max. Current 10~200 A Turns Ratio 1:1000/2000/2500 Pr...
.../5000/10000 Primary Current 10 A Secondary Current 1/2/4/10 mA Burden (Rb) 5~100 Ω Accuracy Class 0.1/0.2/0.5 Class DC Immunity Error <3% Busbar Type as required Mounting Method as required Accept Customized Yes Product Description 1. Double Insulation 2...
...type indoor current transformer made in china The BH series of current transformers have been especially designed to facilitate their installation in new or already existing networks. Thanks to its split cor...
Best Material Block Type 300/5A LV Class 0.5 Current Transformer With Electronic Meter BH-0.66HIII current transformer mainly used in three-phase busbar vertical circumstance,it belongs to enlarged type CT,have...
...Current Transformer Measurement Instrument The current transformer of the type GFLZZ0967-10C5 is casting resins and fully enclosed . It is used for metering electric energy and current , relay protection in...
... transformer is composed of a closed core and windings. Its primary winding has a few turns, which are stringed in the line where the current needs to be measured. Therefore, it often has all the current flo...
... transformer is composed of a closed core and windings. Its primary winding has a few turns, which are stringed in the line where the current needs to be measured. Therefore, it often has all the current flo...
...current transformer minus primary with electric wire slot type primary current transformers Suitable for single-phase electricity meter as well as anti-tempering electricity meter Compact and delicate ...
... 12 Ω Primary Current 4 mA Insulation (Winding to Body) 4 kV Secondary Voltage 20 Ω Core Materail Coiled Silicon Steel Sheet Outer Case Materail Insulation Tape Busbar Type None Mounting Method Through Hole ...
...current transformer Zero Sequence Current Transformer for SMPS 4KV Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-03-03B-1 Turns Ratio 1:200 Resistance 12 Ω Primary Current 2A/1...
...Type 10kv 11kv 12kv Outdoor CT Current Transformer 1.rated insulation level: 12/42/75kV 2.rated frequency: 50/60Hz 3.burden power factor): COSØ=0.8 lagging 4.technical standard accords with):outdoor 5. techn...
...:common product not exceed 1000m,plateau type product not exceed 4000m. Main Technical data: Rated insulation:12/42/75kV(10kV products),40.5/95/185kV(35kV products). Rated frequency:50Hz or 60Hz Rated second...
80mm ZCT80 Zero Phase Current Transformer 0.3A 3kV for Relay Protection Description: This type of current transformer is used indoor to measure the current and energy and perform relaying protection in AC circu...