| Sign In | Join Free | My burrillandco.com |
|
...(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-T500 5 20 5 0.1 10 Current Error % Phase Error ±(') 5%I 20%I 100%I 400%I 800%I Imax 5%I 20%I 100%I 400%I 800%I Imax ≤0.10 ≤0.10 ≤...
..., EV charger, switching cabinet, medical equipment, circuit protection, electrical machine 2. Specification: PN Ib(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-T500 5 20 5 0.1...
... Ib(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-C500 5 20 5 0.1 10 Current Error % Phase Error ±(') 5%I 20%I 100%I 400%I 800%I Imax 5%I 20%I 100%I 400%I 800%I Imax ≤0.10 ≤0.1...
..., EV charger, switching cabinet, medical equipment, circuit protection, electrical machine 2.Specification: PN Ib(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-C500 5 20 5 0.1 ...
...Current Transformer Relay CT With Anti-magnetic 500mT 1.Overview: ● Max Measurement Range to 120A ● High Accuracy Up to 0.1 Class ● 500mT Permanent Magnetic Immunity ● Widely Used for Anti-tamper ● Widely us...
Mini current transformer 100A DCT U type primary terminal for energy meters Characteristics: 1, Used as a current sensing device for utility energy meter; 2, Moisture-proof and vibration-resistant; 3, Encapsula...
Zero phase current transforme zero phase ZCT for ammeter 30A PIN type Applications : 1. Residual current circuit breaker 2. Earth Leakage protection switch 3. Leakage circuit protection Breaker 4. Leakage circu...
...current transformer 100~400A motor protection isolation voltage 3000V Features and application: High accuracy, good consistency, for motor protection Structural parameter: Front view Lateral view The main te...
... Ib(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-C500 5 20 5 0.1 10 Current Error % Phase Error ±(') 5%I 20%I 100%I 400%I 800%I Imax 5%I 20%I 100%I 400%I 800%I Imax ≤0.10 ≤0.1...
...(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-T500 5 20 5 0.1 10 Current Error % Phase Error ±(') 5%I 20%I 100%I 400%I 800%I Imax 5%I 20%I 100%I 400%I 800%I Imax ≤0.10 ≤0.10 ≤...
..., EV charger, switching cabinet, medical equipment, circuit protection, electrical machine 2. Specification: PN Ib(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-T500 5 20 5 0.1...
..., EV charger, switching cabinet, medical equipment, circuit protection, electrical machine 2.Specification: PN Ib(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-C500 5 20 5 0.1 ...
...Current Transformer Relay CT With Anti-magnetic 500mT 1.Overview: ● Max Measurement Range to 120A ● High Accuracy Up to 0.1 Class ● 500mT Permanent Magnetic Immunity ● Widely Used for Anti-tamper ● Widely us...
...-11 Electronic Combined Instrument Transformer Current Transformer Voltage Transformer JDZX10-12R voltage transformer, epoxy resin casting and full enclosed construction, is used indoor for measuring current...
...Current Transformer, Various Types are Available,Current up to 50A FEATURES: High frequency current transformer Low-profile Current: up to 50A High frequency (1kHz to 1MHz) Strong anti-magnetic disturbance e...
...Current Transformer for PCB Protection Circuits The ACST010F/FH Series is a high performance High Frequency Current Transformer designed for accurate pulse current detection and circuit protection in switchi...
...Current Transformer ACSTER11.5 Series – High Isolation, Low DCR, Up to 50A The ACSTER11.5 Series SMD Current Transformer is designed for high-performance current sensing in compact electronic systems. Featur...
Silicon Steel Power Coil Current Transformer For Monitoring Suitable for electrical fire monitoring systems Flexible output method Through structure ,epoxy resin casting,good stability High permeability permall...
Silicon Steel Power Coil Current Transformer For Monitoring Suitable for electrical fire monitoring systems Flexible output method Through structure ,epoxy resin casting,good stability High permeability permall...
...PCB Design ● Withstand Voltage No Less Than 3KV 2.Technical Parameters: Basic Parameter Primary Current(A) Secondary Current(mA) Resistance Rb (Ω) Maximum Current(A) Class Frequency 1 0.5 10 10 0.1 50-60 Hz ...