... represents the arm of the child. The handle is provided with an extension, 464,3 mm long and the probe should be applied with or without this extension, whichever is the more onerous condition. Both joints ...
... C ( Test Probe C) is the necessary tool to proceed protecting electric shock test of household and similar electrical appliances. Technical parameters: 1. Rod length: 100 mm 2. Rod diameter: 2.5 mm 3. Circu...
... Probe D) is the necessary tool to proceed protecting electric shock test of household and similar electrical appliances. Technical parameters: 1. Wire length: 100 mm 2. Wire diameter: 1.0 mm 3. Circular-baf...
... Test Probe C IP3X Test Rod 2.5mm Basic Introduction: 1. According to: GB/T4208-2008 / IEC 61032:1997 / IEC 60529:2001 / IEC 60065 / IEC 60598 and UL 2. IP3X Test Probe C ( Test Probe C) is the necessary too...
...Test Probe D IP4X 1 mm Test Wire with 3N Force Basic Introduction: 1. According to: GB/T4208-2008 / IEC 61032:1997 / IEC 60529:2001 / IEC 60065 / IEC 60598 and UL 2. IP4X Test Probe D ( Test Probe D) is the ...
... tool to proceed protecting electric shock test of household and similar electrical appliances. Technical parameters: 1. Rod length: 100 mm 2. Rod diameter: 2.5 mm 3. Circular-baffle ......
...Test Probe Product overview: The Joint Test Probe of Figure meets the standard requirements of UL507 Fig 9.2 (PA100A), IEC 62368-1:2018 clause 4.8, 5.3.2, 8.5.4.3, V.1.2 and figure V.1, etc., UL474 Fig 5.1, ...
... V.1.6,. This rod probe is intended to verify the protection of persons against access to hazardous parts. It is also used to verify the protection against access with a wire. can be used for anti-electric s...
.... Used to check the security of parts that snap together. The spring gauge assembled in the handle can be calibrated to the neccessary force for using the instrument. This probe is make of stainless steel wi...
.... It is also used by the standards of CSA, IRAM, UL. IEC 60335, IRAM 4220-1 and in most of the rules involved in the verification of accessibility to live parts. The Rigid Test Finger was made on stainless s...
... 60950 Test Probe Kit Meets IEC 60950. Accessibility probes are used to test the size of openings to ensure that fingers and objects do not have access to hazardous parts in equipment and machinery. Safety T...
...Test Pin of IEC 61032 Figure 8 - Test Probe 12 This pin is intended to be used on appliances for verifying the inaccessibility of hazardous live parts or hazardous mechanical parts which are liable to be tou...
...Probe HT-I24 Standard:IEC60335-2-14 CI.20.102. Application:It is used to test whether the blade of hand-held stirrer is completely concealed from above and flat surface can be touched when the blade is rotat...
... of solid foreign objects having a diameter of 12.5mm or greater. Customizable: used for enclosure protection test when open threaded hole of M6 at the end of the handle (connected with pull and push dynamom...
RF Probe RF11GSMPM Performance Item Spec Item Spec Impedance 50 Insertion Loss 0.05dB max. (DC to 3GHz) 0.25dB max. (3GHz to 6GHz) 0.35dB max. (6GHz to 11GHz) Freq Range DC11GHz Temperature Range -45+85 Co...
RF Probe RF11GSMPM Performance Item Spec Item Spec Impedance 50 Insertion Loss 0.05dB max. (DC to 3GHz) 0.25dB max. (3GHz to 6GHz) 0.35dB max. (6GHz to 11GHz) Freq Range DC11GHz Temperature Range -45+85 Co...
Small Finger Probe 8,6 Test Probe 18 of IEC 61032 Conforms to: Standard IEC61032-1997. IEC 61032 Figure 12 – Test probe 18 (small finger probe ∅ 8,6) – Finger: metal material – Handle: insulating material Techn...
#detail_decorate_root .magic-0{width:750px}#detail_decorate_root .magic-1{overflow:hidden;width:750px;height:393px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-2{margin...
Standard probe for eddy conductivity meter of TMD-105 Probes B type machine with diameter 14 mm working frequency of 60 KHz and diameter 8mm working frequency of 500 KHz of a probe; The probe is made of importe...
...standards of CSA, IRAM, UL. IEC 60335, IRAM 4220-1 and in most of the rules involved in the verification of accessibility to live parts. The Jointed Test Finger was made on stainless steel and Polyamide hand...