| Sign In | Join Free | My burrillandco.com |
|
...Sensor Is A cConstant Potential Electrolytic SO2 Sensor SO2 And O2 Undergo Corresponding REDOX Reaction At The Working Electrode And The Opposite Electrode And Release Charge Product description: ME4-SO2-E4 ...
...O2 Electrochemical Gas Sensor Oxygen Detector Features: Product type CLE-0231-400 Measuring range 0 to 30% O2 Load 90% O2 Output signal 350 ± 50 μA in air Baseline <20 μa (nitrogen) Resolution 0.1% O2 Response time (T90) £30 seconds linearity Long-term stability <2% signal value /3 months Working condition Operating temperature -20 ℃ to 50 ℃ Operating Humidity 5 to 90%RH (non-condensing) Working......
...O2 Gas Sensor ► Specification of City MOX3 Medical Oxygen O2 Gas Sensor Product Name City MOX3 Medical Oxygen O2 Gas Sensor Brand City Model Number MOX3 MOX-3 Operating Principle Partial pressure electrochem...
... analyzers. Performance: Output μA@20.9%O2, 22℃ 60~85 Response time t90 from 20.9% to 0% O2(s) (47Ω load) <15 Zero current μA@99.99%N2,22°C <2.5 Features: (1) Measurement range of oxygen concentration (%): 0-30 (2) Working life: > 36 months when...
...O2 Electrochemical Oxygen Gas Sensor Features: Product Model: CLE-0231-400 Range: 0 to 30% O2 Maximum load: 90% O2 Output signal: -350 ±50 μA in air Baseline: -40 ~ 10 μA (nitrogen) Resolution: 0.1% O2 Respo...
...O2 CLE-0231-40S Electrochemical Oxygen Concentration Monitoring Gas Sensor Features: Product model CLE-0231-40S Range 0 to 30% O2 Load 100 ppmSensitivity 1.4 ± 0.6 mA/ppm Baseline (20℃) <± 0.4 mA Baseline drift is equivalent to 0 to 0.5 ppm (-20 to 40℃)Resolution 0.1ppm Response time (T90) £60 seconds linearity Long-term stability <2% Working......
...sensor MOX-3 O2 cell with Data socket Description of Oxygen sensor: The Citytech MOX-3 O2 sensor, a vital component designed for use in various medical equipment applications. This high-quality sensor is eng...
O2 Oxygen Sensor Test Pipe Extension Extender Adapter Spacer Bung The O2 Oxygen Sensor Test Pipe Extension is Made of high quality Stainless Steel, durable for use. They are very easy to install by unscrewing y...
Original SR 11 75 KE4 Medical Oxygen Sensor O2 Cell CE Approvaled Product Description PSR-11-75-KE4 O2 cell Original oxygen sensor O2 sensor Measuring Range 0-100% Accuracy +/-2% of Full Scale Linearity +/-2% o...
...O2 Cell OOM202 Envitec Oxygen Sensor Medical For Draeger Original O2 Cell OOM202 Envitec Medical Oxygen Sensor for Draeger Features: Envitec OOM202 Medical oxygen sensor , Compatible OOM202 O2 CELL Replaceme...
...O2 Oxygen Sensor Use For CPAP Machines Lead Free A wide range of LEAD-FREE Galvanic Oxygen Sensor as a direct replacement with major Anesthesia machines, Respiratory ventilators, Incubators, CPAP machines an...
O2-G2 Oxygen Gas Sensor Small Size 2 Years Working Life 7G Weight O2-G2 Applications: 1. Oxygen alarm 2. Atmosphere Analyzer Datasheet: Temperature Range -30 - 55C Pressure range 80 - 120Kpa ......
...O2) Gas Sensor Part Numbers: AA015-000 For Oxygen Analyzers 2-Electrode Electrochemical Document Purpose: The purpose of this document is to present the performance specification of the CNLH oxygen gas senso...
... sensor. This document should be used in conjunction with the 4OxLL / 5OxLL (Emissions) Characterisation Note, the 4OxLL / 5OxLL Operating Principles (OP19) and the Product Safety Datasheet (PSDS 5). The dat...
... dissolved oxygen sensors uses a new type of fluorescence lifetime technology and high performance fluorescent materials. The fluorescent dissolved oxygen sensor is based on the quenching principle of the sp...
...: ME2-O2-Φ20 0 ~ 25%vol Electrochemical Oxygen Sensor Is Used For Oxygen Detection In Industrial Mine Storage And Environmental Protection Fields Features: Me2-o2-20 Oxygen sensor is a galvanic cell type sen...
... System 30 Nm3 / H O2 Capacity Working Principle Atmospheric desorption PSA oxygen generator use the clean compressed air as raw material,zeolite molecular sieve as the adsorbing material ,use the pressure s...
...O2 sensor is used in Bacharach portable combustion analyzers to measure the percentage content of oxygen levels in flue gases. The range of the oxygen sensor is 0 – 20.9%. O2 measurement is used in conjuncti...