...Camera Character Generator Olympus OTV-S4 is used to transmit endoscopic images for easy observation by the surgeon during the procedure. It can work with endoscopes, rigid and fiber optic cameras. Features ...
...Olympus S7 & S7 Pro Camera Head The cable for Olympus S7 & S7 pro camera is brand new and compatible. They are flexible, durable, and relatively inexpensive. The cable complies with the ROHS standard directi...
OLYMPUS CF-HQ190L Repair Problem: 1, Image display; 2, Light bundle broken about 10%; 3, Insertion tube is ok; 4, Biospy channel worn and leaking; 5, The upper angle broken, helix tube and bending section were ...
OLYMPUS A-4801A VIDEOLAP LAPAROSCOPE, 10MM,0, AUTOCLAVABLE WSTERILIZATION CASE Description: Brand Name: OLYMPUS Name: OLYMPUS A-4801A VIDEOLAP LAPAROSCOPE PN: A-4801A Notes from company: Order: Medical parts a...
Olympus CF-240L Colonoscope for repair Brief Description Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch. Solution: Replace rubber, objective lens...
OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR Brief Description Fault: 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leaka...
Olympus GIF-Q150 gastroscope for repair Brief Description Fault: 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and ...
Olympus GIF-H180J gastroscope for repair Brief Description Fault: 1.image with shadow; 2.light bundle broken; 3.insert tube with bite mark; 4.biopsy tube abrasion; 5.bending section serious deformation; 6.wir...
Olympus CHF-P20Q endoscope for repair Brief Description Fault: 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution: Replace image bu...
Olympus CF-2T160L Colonoscope for repair Brief Description Fault: 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wi...
Olympus BF-XP160F fiber scope for repair Brief Description Fault: 1. Image degumming, serious color, CCD aging, a few black and gray spots; 2. 20% of the light bundle is broken; 3. Insert tube aging slightly;...
Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair Brief Description Fault: 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section ...
Olympus CF-240AI Colonoscope for repair Brief Description Fault: Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging. Solution: Replace in...
Olympus CYF V2 Cystoscope For Repair Brief Description Fault: Leakage. Solution: Replace the insert tube, light bundle, biopsy channel, bending section, wire, steel mesh, rubber. Problem & Solutoin Brand Oly...
GIF-XQ240 Gastroscope by Olympus for repair Brief Description Fault: Leakage. Solution: Replace light guide tube,NO.1 button,wire,mesh,adjust angle. Problem & Solutoin Brand Olympus Model GIF-XQ240 Fault Lea...
Olympus GIF-Q150 Gastroscope for repair Brief Description Fault: 1. With image; 2. Light bundlebreak badly 3. Insert tubeaging; 4. Biopsy tubeabrasion, leakage badly; 5. Angle tied, bendingsection, wires and...
Olympus A4674A Autoclavable Hysteroscope for repair Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Rep...
CH-S190-08-LB Camera Head Endoscope Inspection Camera Medical Camera Scope Olympus CH-S190-08-LB - The new ergonomically designed camera is small and light, specifically designed for urological surgery. It help...
... control capabilities. With 1.2x magnification, you can zoom the image up to 1.5x and maintain hd image quality even in zoom mode. The camera head control part has three switches, programmable to achieve com...