| Sign In | Join Free | My burrillandco.com |
|
... behavior under forced internal short-circuit conditions. This advanced equipment combines temperature control, mechanical squeezing, real-time voltage acquisition, and comprehensive safety protection within...
...Testing and sorting Machine,18650 automatic sorter machine Electricity Source: Single-phase 220VAC power: 1.5KW Working gas source: 0.4-0.6MPa Adaptation battery: 18650,26650,32650,21700 ect Efficiency: 5000...
...Testing and sorting Machine,18650 automatic sorter machine Electricity Source: Single-phase 220VAC power: 1.5KW Working gas source: 0.4-0.6MPa Adaptation battery: 18650,26650,32650,21700 ect Efficiency: 5000...
...geophone, which is widely used to do geophysical exploration, engineering vibration test, Type SG10 10hz Seismic Geophone Natural frequency ( Hz ) 10Hz±2.5% Open circuit damping 0.68±5% Sensitivity (v/m/s) 2...
...Test Equipment 3KG Weight Technical Specification: Model HY2305 Rated Voltage 250V 500V 1000V 2500V 5000V Measuring Range 0.0~99.9MΩ 100~999MΩ 1.00~10.0GΩ 0.0~99.9MΩ 100~999MΩ 1.00~9.99GΩ 10.0~20.0GΩ 0.0~99....
... Voltage at Maximum Power-Vmp (V) 34.0 34.2 34.4 Current at Maximum Power-Imp (A) 9.87 9.96 10.04 Open Circuit Voltage-Voc (V) 41.5 41.7 41.9 Short Circuit Voltage-Isc (A) 10.36 10.55 10.64 Module Efficiency...
... - Supply 2.7 V ~ 38 V Current - Supply (Max) 2.7mA (Typ) Current - Output (Max) 30mA Output Type Open Drain Features Temperature Compensated Operating Temperature -40°C ~ 150°C (TA) Package / Case TO-226-3,...
...) 500µA Current - Output (Max) 10mA Output Type Open Drain Features - Operating Temperature -40°C ~ 85°C (TA) Package / Case TO-236-3, SC-59, SOT-23-3 Supplier ......
... Sensing Range 15mT Trip, 3mT Release Test Condition 25°C Voltage - Supply 4.2 V ~ 28 V Current - Supply (Max) 4mA Current - Output (Max) 25mA Output Type Open Drain Features Temperature Compensated Operatin...
...Polarization Either Sensing Range ±7mT Trip, ±1mT Release Test Condition -40°C ~ 150°C Voltage - Supply 2.4 V ~ 5.5 V Current - Supply (Max) 2mA Current - Output (Max) 1mA Output Type Open Drain Features - O...
... Sensing Range 4.5mT Trip, -4.5mT Release Test Condition 25°C Voltage - Supply 3.8 V ~ 24 V Current - Supply (Max) 4.2mA Current - Output (Max) 20mA Output Type Open Drain Features Temperature Compensated Op...
...Sensing Range 6mT Trip, 0.5mT Release Test Condition -40°C ~ 125°C Voltage - Supply 2.7 V ~ 38 V Current - Supply (Max) 2.7mA (Typ) Current - Output (Max) 30mA Output Type Open Drain Features Temperature Com...
...South Pole Sensing Range 6mT Trip, -6mT Release Test Condition 25°C Voltage - Supply 3 V ~ 20 V Current - Supply (Max) 6mA Current - Output (Max) 25mA Output Type Open Collector Features - Operating Temperat...
... (Typ) Current - Output (Max) 2mA Output Type Open Drain Features - Operating Temperature -40°C ~ 85°C (TA) Package / Case TO-236-3, SC-59, SOT-23-3 Supplier ......
...Sensing Range 3.5mT Trip, 2.5mT Release Test Condition -40°C ~ 150°C Voltage - Supply 2.8 V ~ 5.5 V Current - Supply (Max) 4mA Current - Output (Max) 5mA Output Type Open Drain Features Temperature Compensat...
...South Pole Sensing Range 10mT Trip, 8mT Release Test Condition 25°C Voltage - Supply 3 V ~ 28 V Current - Supply (Max) 4mA Current - Output (Max) 60mA Output Type Open Drain Features - Operating Temperature ...
... Either Sensing Range ±4mT Trip, ±1mT Release Test Condition 25°C Voltage - Supply 2.5 V ~ 5.5 V Current - Supply (Max) 16µA Current - Output (Max) - Output Type Open Drain Features - Operating Temperature -...
...) 4mA Current - Output (Max) 60mA Output Type Open Drain Features - Operating Temperature -40°C ~ 150°C (TA) Package / Case TO-236-3, SC-59, SOT-23-3 Supplier ......
...) 4mA Current - Output (Max) 60mA Output Type Open Drain Features - Operating Temperature -40°C ~ 150°C (TA) Package / Case TO-236-3, SC-59, SOT-23-3 Supplier ......