... 660V Application low voltage and high voltage Certification CE,ROHS,UL for material Operating Temperature 30℃~120℃ Place of Origin China Insulator is the special part to fix,......
...below. For Layling indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Standards Description CU/XLPE/STA/PVC, IEC ......
...MV Armoured Cable Applications Used for Power transmission and distribution line with voltage rated at 35kv and below. For Layling indoors and outdoors. Able to bear certain traction during installation, but...
...protective relaying in the single-phase or three phase power system with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV. Technical Data: 1,Installation site: Outdoor 2,Rated frequency: 50/...
...Medium Voltage Load Bank With Three Control Ways Product Description 1. It is of high power density, no red hot phenomenon and automatic protection function overheated. 2. It can’t be overheated and broken w...
... be overheated and broken when the fans stop working 3.The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client’s req...
1.Product name:Electric wire cable XLPE 11kV underground armoured power cables 2.Voltage:medium voltage 6/10kV 8.7/15kV 21/35kV 26/35kV 3.Conductor:Copper 4.Insulation:XLPE 5.Armour:Steel tape armour, Steel ......
... or other standards as request. 2. Rated Voltage: 0.6/1KV 6/10KV;8.7/15KV;12/20KV;18/20KV;21/35KV;6/35KV 3. Construction: Conductor:Copper Insulation:XLPE ......
... energy, distribution of electrical energy. Standards: ICEA S-94-649, CSA C68.3, CSA C68.5 Rated Voltage: 5KV, 8KV, 15, 25, 28 kv, 35, 46KV Constructure: Conductor: Copper / Aluminum Conductor screen: Semi-....
Copper / AL XLPE PE NA2XSY Copper wire+Tape Metallic Screen 630 Sqmm Medium Voltage Power Cables Application: The product is used in power transmission and distribution line at voltage up to 46KV. It does not o...
...Metallic Screen 11KV 300 Sqmm Underground Medium Voltage Power Cables 1. Standard: According to GB12706( Equal to IEC60502)Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards as request. 2. ...
...Medium Voltage Power Cables 18/30 KV (36KV) 3 X 240 Mm² Application: The cable can be used for underground power transmission . The cable can bear external mechanical pressure and moderate pulling force with...
...Medium Voltage Power Cables , XLPE Insulated Power Cable Câble unipolaire Alu 1 x 240 mm² - 18/30 (36) KV Application: The cable can be used for underground power transmission . The cable can bear external m...
...Medium Voltage Concentric Cables Copper wire Metallic Screen Application: The xlpe single core concentric neutral cables rated 5 to 45KV which are used for the transmission and electrical energy, distributio...