...Protector YJ62/300B 120V 60HZ Ball Bearings This piston compressor pump is designed with a special pump. A piston pump contains an accurately machined die-casted piston moving in a cylinder normally fitted w...
Motor Protector Busbars 10VA Low Voltage Ct 0.2s High Accuracy Split-core current transformers are built primarily for power grid construction or retrofit projects, ......
35mm Din Rail Impulse Discharge Current 25kA Surge Protector With PBT Plastic OBV-I25-1 data: Uc(maximum continuous operating voltage) 275V Iimp(impulse discharge current for class I test) 25kA Up(voltage prote...
... Protector Multi-Layer GDT Structure OBV50/160 Data Uc(maximum continuous operating voltage) 275V Iimp(impulse discharge current for class I test) 50kA Imax(maximum discharge current) 160kA In(nominal discha...
Lower Protection Level 30kA Surge Protector For 320V N-PE System OBV-I30 data: Uc(maximum continuous operating voltage) 320V Up(voltage protection level) ≤1.9kv suitable power system 1-N/E, single phase Respons...
1+2 class 100kA surge protector SPD OBV-I25: Rated voltage(VDC) 230/400Vac Iimp(impulse discharge current for class I test) 100KA In(nominal discharge current for class II test) 100kA Up(voltage protection leve...
1+2 class 100kA surge protector SPD OBV-I25: Rated voltage(VDC) 240/415Vac Iimp(impulse discharge current for class I test) 500KA In(nominal discharge current for class II test) 500kA Up(voltage protection leve...
1+2 class 100kA surge protector SPD OBV-I25: Rated voltage(VDC) 240/415Vac Iimp(impulse discharge current for class I test) 25KA In(nominal discharge current for class II test) 25kA Up(voltage protection level)...
1+2 class 100kA surge protector SPD OBV-I25: Rated voltage(VDC) 240/415Vac Iimp(impulse discharge current for class I test) 15KA In(nominal discharge current for class II test) 15kA Up(voltage protection level)...
120k secondary surge protector SPD OBV-I25: Rated voltage(VDC) 240/415Vac Iimp(impulse discharge current for class I test) 120KA In(nominal discharge current for class II test) 60kA Up(voltage protection level)...
120k secondary surge protector SPD OBV-I25: Rated voltage(VDC) 240/415Vac Iimp(impulse discharge current for class I test) 30KA In(nominal discharge current for class II test) 60kA Up(voltage protection level) ...
120k secondary surge protector SPD OBV-I25: Rated voltage(Un) 48Vac Iimp(impulse discharge current for class I test) 3KA In(nominal discharge current for class II test) 6kA Up(voltage protection level) 0.8kv r...
... surge protectors protect against surges affected by indirect lightning and direct lightning The main technical parameters Model and specification U1-II20X Uc(VAC)Maxi continuous operating voltage 1000,750,4...
... series surge protectors protect against surges affected by indirect lightning and direct lightning The main technical parameters Model and specification U1-II20X Uc(VAC)Maxi continuous operating voltage 275...
unNominal working voltage (Un)1000V surge protector breaker Model and specification AM40-1000 Model AM40-1000 MainTechnicalData UnNominalworkingvoltage(Un) 1000V UcMaxcontinuousoperatingvoltage(Uc) 1100VAC Nomi...
Lightning Protection Device Solar PV 40kA Low Voltage DC Surge Protector Device DC surge protection device (NDU6) used in lightning protection of solar photovotaic power generation system or other DC power ......
...Voltage Protection OBV5-B60 series Class B+C surge protection devices (Type I+II Surge Protectors) is perfect for any kind of building being it residential, commercial, industrial and so on, these devices wo...
... , Surge Protective Device *DC surge protector is an electrical component used to limit transient over-voltage phenomenon. Because it needs to operate for a long time, there will be aging. If the DC surge pr...
...Protector For lightning Protection OBV5-I-25 OBV10-I-25 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are ...
Wholesale 3 Phase 20-40ka 385V Type 2 Surge Protector for Low Voltage According to the standard elevator power distribution cabinet, it is necessary to install a surge protector, and the elevator is responsible...