Olympus CYF V2 Cystoscope For Repair Brief Description Fault: Leakage. Solution: Replace the insert tube, light bundle, biopsy channel, bending section, wire, steel mesh, rubber. Problem & Solutoin Brand Oly...
GIF-XQ240 Gastroscope by Olympus for repair Brief Description Fault: Leakage. Solution: Replace light guide tube,NO.1 button,wire,mesh,adjust angle. Problem & Solutoin Brand Olympus Model GIF-XQ240 Fault Lea...
Olympus GIF-Q150 Gastroscope for repair Brief Description Fault: 1. With image; 2. Light bundlebreak badly 3. Insert tubeaging; 4. Biopsy tubeabrasion, leakage badly; 5. Angle tied, bendingsection, wires and...
Olympus A70940A Autoclavable Arthroscope for repair Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1....
Olympus A4674A Autoclavable Hysteroscope for repair Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Rep...
Karl Storz 27005BA Cystoscope for repair Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Rep...
Stryker 30 0502-503-030 laproscope for repair Brief Description Fault: Image blur, objective lens loose without glue, inner optical parts broken. Solution: Add glue for objective lens, replace inner optical ...
LINVATEC HD 4300 Arthroscope for repair Brief Description Fault: Image with black shadow; eyepiece with scratches, inner optical parts broken. Solution: Replace objective lens, inner optical parts, clean and ...
...,yellow,black Packing 1.Sample order less than 50meters packed folded then plastic bag and carton case outside 2.Regular order packed in roll,then carton case or plywood case outside Delivery Delivery Time 1...
..., the AED needs to be properly stored and carried to ensure it remains in optimal working condition in an emergency. The small and lightweight size of this carrying case makes it easy to...
Mindray DECG-03A Upper Case Upper Cover Casing MS1-30245 for Mindray DECG-03A ECG EKG (ELECTROCARDIOGRAPH) Machine Brief Description Mindray DECG-03A Upper Case MS1-30245: As the outermost protective layer of...
...Case for MINDRAY DECG-03A ECG EKG ( ELECTROCARDIOGRAPH) Machine Used-Good Condition ► Brief Description Back Cover Case for MINDRAY DECG-03A ECG Machine: This is a crucial component of the device, forming th...
...Components ► Brief Description The ECG-1210 ECG printer components consist of a printer casing and rollers. The casing is made of sturdy and durable white plastic, and the rollers are made of two stainless s...
...Brief Introduction: iqualitrol dust proof testing chamber is according to IEC60529, IEC 60598, GB2423.37-89 (Test L:dust test methods), GB 4208-93 protective casing grade (IP code), GB/T 4942.2-93(protective...
... of Belt Pumping Unit TJA Series of casing and tubing coupling bucking unit is widely applicable for casing and tubing manufacturing, and oil field service. Among which the TJA series is the most representat...
...plastic handle allows customers to take away this case easily. This tinplate DVD case with metal lock and plastic handle allows customers to take away this case easily. Inside this DVD tin box, there is a hi...
... around the casing during cementing operations. The single piece casing centralizer is made from special high strength steel (65Mn steel), which gives more excellent hardness and spring action than other typ...
... (device) is a complete, acute, cardiaccare response system with both manual and semiautomatic defibrillation operation. When clinically indicated, the device enables the operator to deliver a brief, high-en...