Double Arms Tapered Galvanized Steel Pole For Electrical Power Lines Specifications 1. Protecion class: IP65 2. Light source: 100W-400W high-pressure sodium lamp 3. Rated voltage and frequency: 220V(10%)/50Hz ...
... DC contactor is mainly used for remote making and breaking DC power lines of rated DC working voltage up to 660V and rated working current up to 1500A , it is suitable for different starting , stop , commut...
HV ceramic transformer porcelain bushing insulator in gray color / US market Description: ANSI CLASS Height(mm) Creepage distance (mm) Dry arcing distance (mm) BIL(kV) Torsion strength (N.m) 18kV 422 460 220 12...
Professional ACSR Splicing Sleeve Protector For Power Lines 1. Professional Protection Performance Provides mechanical and environmental protection for ACSR splices Withstands voltages up to 35kV UV resistant...
... liner Product Description: The Conductor Stringing Blocks are essential equipment used in construction works for the efficient installation of power lines. Specifically designed for the transmission industr...
R438 Product Description TECHNICAL Data SENSING INPUT Voltage: 95-480VAC POWER INPUT Voltage: 40-150VAC, 3 phase Magnetic Field OUTPUT Voltage: Max 160VDC at 120VAC input Current Continuous 8A PRESSURE REGULATI...
R448 Product Description TECHNICAL Data SENSING INPUT Voltage: 95-480VAC POWER INPUT Voltage: 40-150VAC, 3 phase Magnetic Field OUTPUT Voltage: Max 160VDC at 120VAC input Current Continuous 10A PRESSURE REGULAT...
R450 Product Description TECHNICAL Data SENSING INPUT Voltage: 95-480VAC POWER INPUT Voltage: 40-150VAC, 3 phase Magnetic Field OUTPUT Voltage: Max 160VDC at 120VAC input Current Continuous 10A PRESSURE REGULAT...
EA440-T Product description TECHNICAL DATA SENSING INPUT Voltage: 95~480VAC Power INPUT Voltage: 100~264VAC, 1 Phase MAGETIC Field OutPut Voltage: Max 90VDC at 207VAC input Current: Continuous 4A, Intermittent ...
EA08/EA125-8 Product description TECHNICAL DATA SENSING INPUT Voltage: 95~480VAC Power INPUT Voltage: 40~150VAC, 3 Phase MAGETIC Field OutPut Voltage: Max 150VDC at 200VAC input Current: Continuous 8A, max 12A ...
EA16 Product description TECHNICAL DATA SENSING INPUT Voltage: 170~480VAC, 1 phase 2 wire with toggle switch options Power INPUT Voltage: 100~300VAC, 1 phase 2 wire MAGETIC FIELD OUTPUT Voltage: Max 90VDC at 24...
EA05A Product description TECHNICAL DATA SENSING INPUT Voltage: 220/380/440VAC, 1 phase 2 wire POWER INPUT Voltage: 100~300VAC, 1 phase 2 wire MAGETIC FIELD OUTPUT Voltage: Max 90VDC at 240VAC input Current: Co...
... Description TECHNICAL DATA SENSING INPUT Voltage: Terminal 1 2 3 4 5 6 can be connected to Y or 220~480VAC Single phase / Three phase 50/60 Hz POWER INPUT Voltage: 50~280VAC(1,2), 50/60 Hz MAGNETIC FIELD OU...
M16FA655A Product Description TECHNICAL DATA SENSING INPUT Voltage: 110/220/400 VAC POWER INPUT Voltage: 170~270VAC,1 phase 2 wire MAGNETIC FIELD OUTPUT Voltage: Max 95VDC, 240VAC input Current: Continous 8A Co...
Overhead Power Line Aerial Spacer Trolley Cart for 2 bundle conductor Item number Model Rated Load(KN) Maximum through diameter(mm) ......
FJZ4 Type Four Split Conductor Aluminum Alloy Spacer Damper For Overhead Line Quick Details Brand Name: GZXYHY Model Number: FJZ4 Material: Alunimiun alloy Color: Silver Operation: Convenient Installation: Easy...
Power Line Construction Tools Double Head Type Mesh Sock Joints Cable Sleeve Connector DOUBLE HEAD TYPE Model ......
Power Line Construction Tools Double Head Type Mesh Sock Joints/Wire Rope Temporary Mesh Sock Joint DOUBLE ......
Hydraulic Tensioner 2x40KN Stringing Equipment For Overhead Power Lines 2x40KN Stringing Equipment Description: The machine allows for the tension stringing of twin-bundle conductor of 630mm2 and below in mount...
TY90 Puller Machine For Overhead Line With 118kw(158hp) Cummins Engine TY90 Hydraulic Puller This machine allows for the tension stringing of twin-bundle conductor of 500mm2 and below in mountainous and hilly a...